ArticleJournal of medical physics
Evaluation of Two Commercial Artificial Intelligence Segmentation Systems for Radiation Therapy.
Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To assess the clinical acceptability of artificial intelligence (AI) auto-segmentation systems by comparing their performance with physician expert delineated contours, focusing on evaluating contour accuracy and volume differences. Methods: Thirty-three previously treated head and neck patients were selected for comparison. AI-generated structures were created on each computed tomography scan using two AI systems: MIM Protégé AI and TheraPanacea Annotate. Experts participated in a Turing test to distinguish between AI-generated and manually drawn contours. Experts then evaluated the anonymized structure sets on a 3-point scale (1 = lowest acceptance, 3 = highest). Each patient's structure set was analyzed in MIM, and the volumes (in ml) were recorded. Absolute differences in contour volumes were calculated to assess accuracy. Results: The Turing test showed experienced experts could reliably differentiate between AI-generated and manual contours, while less experienced experts struggled. TheraPanacea outperformed MIM in 60% of the structures based on Dice similarity scores. When TheraPanacea's Dice scores were lower than MIM's, the differences were minimal, with the largest gap being 0.049. However, when MIM had lower Dice scores, the differences were more pronounced, with the largest being 0.21 for the Optic Chiasm. Despite TheraPanacea's higher Dice scores, expert reviews favored MIM; this preference may be due to the long-standing integration of the MIM solution in the clinical workflow, fostering greater familiarity and trust. Conclusions: AI contouring has enhanced the efficiency of radiation therapy planning. This study emphasizes AI-driven auto-segmentation's ability to streamline organ delineation, despite vendor performance differences.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.