Evidence map›Paper›PMID 41939159›Full record

ArticleJournal of medical physics

Commissioning and Quality Assurance of Catalyst

Adhimoolam Saravana Kumar, Juergen Meyer, A Dinesh Babu, Sekar Sankar, Esposito Marco

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Adhimoolam Saravana KumarDepartment of Medical Physics, PSG Hospitals, Coimbatore, Tamil Nadu, India.
Juergen MeyerFred Hutchinson Cancer Center, University of Washington, Seattle, WA, USA.
A Dinesh BabuDepartment of Medical Physics, PSG Hospitals, Coimbatore, Tamil Nadu, India.
Sekar SankarDepartment of Medical Physics, PSG Hospitals, Coimbatore, Tamil Nadu, India.
Esposito MarcoInternational Center for Theoretical Physics, Trieste, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: In this study, we describe and critically review our experience in the commissioning of the surface-guided radiation therapy (SGRT) system from C-RAD (Uppsala, Sweden), integrated with a Varian TrueBeam HyperArc linear accelerator (LINAC). Materials and Methods: The C-RAD SGRT system was commissioned according to the guidelines of the American Association of Physicists in Medicine Task Group 147 and the European Society for Radiotherapy and Oncology-Advisory Committee for Radiation Oncology Practice report. The commissioning tests included the isocenter, camera thermal drift, reproducibility, static localization accuracy with a 6-degree-of-freedom (DOF) couch, dynamic gating delivery, and an end-to-end test. The tools and phantoms employed for this verification included: (a) Sentinel 4DCT daily check device, (b) Catalyst⁺ HD daily check device, (c) Penta-guide, (d) gating phantom, (e) calibration board, (f) Winston-Lutz phantom, and (g) the Little John anthropomorphic phantom. Results/Discussion: The reproducibility of both the Sentinel 4DCT and Catalyst⁺ HD cameras demonstrated accuracy within ± 1 mm. The radiation isocenter measurements for both the Sentinel 4DCT and Catalyst⁺ HD cameras were found to be <1 mm, well within the recommended reports of the relevant international guidelines. The static localization accuracy of the Catalyst⁺ HD camera with a 6DOF couch was determined to be 0.15 ± 0.13 mm, 0.42 ± 0.23 mm, and 0.20 ± 0.15 mm for the vertical, longitudinal, and lateral directions, respectively. The rotational accuracy for roll, pitch, and yaw was found to be 0.05°±0.05°, 0.12°±0.18°, and 0.13°±0.10°, respectively. All results were within the tolerances recommended by the international recommendations and highlight the accuracy and precision of the C-RAD SGRT system in conjunction with the TrueBeam HyperArc LINAC. Conclusion: The newly installed advanced C-RAD SGRT systems have been successfully integrated with the Varian TrueBeam LINAC for clinical use, marking a significant milestone as the first deployment of SGRT technology of its kind in India.

Indexed as

Advanced radiotherapymotion managementoptical imagingsetup verificationsurface guidance

Identifiers

PMID41939159
PMCPMC13046184

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.