ArticleJournal of medical physics

Radiation Dose Assessment in Diagnostic Imaging Using Thermoluminescent Dosimeter-100H Dosimeters and a RANDO Phantom: Insights from Chest, Pelvic, and Skull Examinations.

Sedigheh Sina, Shima Alizadeh, Sadegh Abbasipour, Mozhgan Dalir, Mohaddeseh Heydarinia, Fatemeh Norouzalizadeh, Mobarakeh Nasiri, Mohammad Hossein Sadeghi, Kazem Sadeghi Ebrahim Mohammadi, Elnaz Saeedian and 2 more

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Sedigheh SinaDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Shima AlizadehDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Sadegh AbbasipourDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Mozhgan DalirDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Mohaddeseh HeydariniaDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Fatemeh NorouzalizadehRadiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Mobarakeh NasiriDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Mohammad Hossein SadeghiDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Kazem Sadeghi Ebrahim MohammadiRadiation Research Center, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Elnaz SaeedianDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Minoo ShakerianDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
Mahboobeh SheikiDepartment of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study aims to evaluate radiation doses to the skin, pelvis, and skull during routine radiographic imaging procedures. Materials and Methods: Entrance skin dose (ESD) was assessed using both direct and indirect methods. Direct measurements were conducted with thermoluminescent dosimeter (TLD)-100H TLDs placed on an Alderson RANDO female anthropomorphic phantom. Indirect measurements were obtained using the calibrated output of the X-ray tube. Organ dose estimations were also derived through thermoluminescence dosimetry. Results: Direct measurements yielded ESD values of 0.27 mGy for chest, 2.36 mGy for pelvis, and 2.54 mGy for skull radiography. Corresponding values from the indirect method were 0.26 mGy, 2.29 mGy, and 2.43 mGy, respectively. Conclusions: The radiation dose levels obtained are consistent with the national diagnostic reference levels in Iran. These findings support the ongoing optimization of radiographic practices in alignment with the as low as reasonably achievable principle.

Indexed as

As low as reasonably achievable principleorgan doseradiation dosimetrythermoluminescent dosimeters-100H

Identifiers

PMID41939156
PMCPMC13046188

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.