Evidence map›Paper›PMID 41938058›Full record

ArticleFrontiers in bioengineering and biotechnology2026

A new device and method for detecting the permeability of articular cartilage.

Fuyang Cao, Haibin Deng, Guohao Zhang, Ningning Ma, Binghang Zhang, Xianda Che, Gaige Wu, Pengcui Li, Li Guo, Xiaochun Wei

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fuyang CaoDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Haibin DengDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Guohao ZhangDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Ningning MaDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Binghang ZhangDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Xianda CheDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Gaige WuDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Pengcui LiDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Li GuoDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Xiaochun WeiDepartment of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Articular cartilage relies on synovial fluid for substance exchange, with permeability being a key parameter linked to its physiological functions and degenerative disease mechanisms. Existing detection techniques are limited by detachment from physiological mechanical environments, insufficient quantification accuracy, and poor sealing. This study aimed to develop an accurate, reliable, and physiologically relevant device and method for cartilage permeability detection. Methods: Based on intra-articular convective transport and Darcy's Law, a modular testing device (permeation, pressure supply, central control modules) was fabricated to simulate the synovial fluid-cartilage-subchondral bone unit under pressure. Porcine femoral condylar cartilage samples were tested with 4 N, 8 N, 16 N (n = 6, per group) constant pressure (1800 s) using an ElectroForce 3,200 system. Permeability coefficients were calculated via Darcy's Law-derived formulas. Repeatability (single operator, fixed conditions, n = 6) and reproducibility (multiple operators, unified conditions, n = 6) were verified by CV and ANOVA. Human knee cartilage (n = 6) was used to validate practicality for clinical solutions. Data were analyzed with GraphPad Prism 9.5. Results: Friction force between the push rod and permeation tube was 2.5 N, with no leakage confirmed by eosin dye. Repeatability tests showed mean permeabilities of 1.50 × 10 Conclusion: The developed device and method address traditional limitations, featuring excellent physiological relevance, quantification accuracy, and stability. It provides a pivotal tool for studying cartilage physiology, OA pathology, optimizing repair materials and therapeutic strategies, and improving cartilage injury repair evaluation.

Indexed as

articular cartilageconvective principleDarcy’s lawmechanical loadingpermeability testing

Identifiers

PMID41938058
PMCPMC13043639

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.