Evidence map›Paper›PMID 41938056›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Mechanical stability of the interaction between a lower-limb rehabilitation exoskeleton and the user's body during functional tasks.

Simona Squartecchia, Marco Rabuffetti, Tiziana Lencioni, Johanna Jonsdottir, Alberto Marzegan, Pietro Di Bello, Indya Ceroni, Marianna Semprini, Maurizio Ferrarin

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Simona SquartecchiaIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Marco RabuffettiIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Tiziana LencioniIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Johanna JonsdottirIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Alberto MarzeganIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Pietro Di BelloIstituto Italiano di Tecnologia, Genoa, Italy.
Indya CeroniIstituto Italiano di Tecnologia, Genoa, Italy.
Marianna SempriniIstituto Italiano di Tecnologia, Genoa, Italy.
Maurizio FerrarinIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Lower-limb exoskeletons support gait restoration in individuals with locomotor impairments. Mechanical stability in human-exoskeleton interaction is essential for safety. This pilot study evaluated the interaction stability between TWIN exoskeleton and user by analyzing relative displacements between the exoskeleton cuffs and the corresponding user's thigh and shank during walking (WA) and sit-to-stand (STS). A second parameter quantified the discrepancy between exoskeleton and user joint angles. Methods: Five healthy adults performed STS and WA while wearing TWIN. An optoelectronic system tracked markers placed on anatomical landmarks and exoskeleton segments. The standard deviation of the relative displacement (RDstd) between the exoskeleton and the underlying anatomical segment quantified mechanical stability. Human-exoskeleton kinematic discrepancy (HEKD) was determined as root mean square of the difference between encoder- and motion capture-derived joint angles. Results: During STS, RDstd was 4.6 ± 1.5 mm (thigh) and 1.4 ± 0.1 mm (shank). During WA, values were 3.3 ± 0.4 mm (thigh) and 2.7 ± 0.2 mm (shank). HEKD during WA was 1.7 ± 0.6 deg (hip) and 1.9 ± 0.4 deg (knee), whereas 2.2 ± 0.8 deg (hip) and 3.3 ± 1.3 deg (knee) during STS. No participants reported discomfort or pain during tests. Discussion: All relative displacement values were below 11.7 mm (safety value for the possible onset of skin damages). Larger relative displacements at thigh level during STS than during WA were likely due to larger hip and knee joint excursions associated to STS. Conversely, larger relative displacements at shank level during WA than during STS can be attributed to foot impact forces occurring during WA. Compared to the results from a previous study on a different Hip Active Orthosis, which reported RDstd values at the thigh between 4.0 and 6.3 mm during walking, TWIN showed smaller values, confirming a greater mechanical stability at that level. The small values of discrepancy between exoskeleton and anatomical joint angles during both tasks (below 2 deg during WA and 3.3 deg during STS) indicated strong human-exoskeleton kinematic coupling. Taken together, these findings suggest that TWIN provided high stability during both motor tasks without compromising comfort or safety.

Indexed as

ergonomicsexoskeletonkinematic discrepancylocomotionmechanical stabilitywearable robotics

Identifiers

PMID41938056
PMCPMC13047205

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.