ArticleJournal of Materials Science. Materials in engineering2026
Effects of heat treatment on the temperature coefficient of resistivity of laser fabricated NiCr flexible sensors.
Article in Journal of Materials Science. Materials in engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Advancements in data collection and automation require reliable flexible sensors due to their versatility and customization. One challenge with the practical use of flexible sensors is the change in resistance due to the temperature coefficient of resistivity (TCR) at different use temperatures. This research investigates the heat treatment process for a common metal sensing element, Evanohm (80/20 nickel chromium alloy), to reduce its TCR. NiCr thin films were heat treated in an inert argon environment at various temperatures and hold times, then fabricated into flexible sensors on a polymer substrate using UV nanosecond laser ablation. Sensors were mounted onto an aluminum substrate to provide mechanical backing during testing. Following heat treatment, TCR values as low as 1.44 ppm/°C were achieved at a heat treatment temperature of 475°C for 180 min of hold time. Electrical and microstructural changes were also analyzed to determine the mechanism for TCR change. The results demonstrate the effectiveness of heat treatment in reducing the TCR of NiCr flexible sensors, minimizing the impact of use temperature on resistance change. This research contributes to the development of NiCr flexible sensors with stable and linear resistance behaviour over the temperature testing range from -10°C to 150°C. Supplementary Information: The online version contains supplementary material available at 10.1186/s40712-026-00430-z.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.