Evidence map›Paper›PMID 41937879›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology2026

Automatic pelvic bone segmentation for radiotherapy using diagnostic imaging workstation.

Koji Kosaka, Yoshihiro Ueda, Yuji Kuroki, Hikari Minami, Shoki Inui, Masahiro Morimoto, Ryohei Sasaki

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Koji KosakaDepartment of Radiation Therapy, National Hospital Organization Kobe Medical Center, Hyougo, Japan.
Yoshihiro UedaDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Yuji KurokiDepartment of Radiation Therapy, National Hospital Organization Kobe Medical Center, Hyougo, Japan.
Hikari MinamiDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Shoki InuiDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Masahiro MorimotoDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Ryohei SasakiDepartment of Radiation Oncology, Kobe University Hospital, Hyougo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study evaluated the usefulness of a diagnostic imaging workstation in streamlining procedures and improving the accuracy of contouring pelvic bones with characteristic shapes. Materials and methods: The study included 18 patients with computed tomography (CT) images of the pelvic bone undergoing radiation therapy planning. Four pelvic bone structures (ST) were created: ST_EZ1, ST_EZ3, ST_Zio, and ST_MN. ST_EZ1 and ST_EZ3 using the automatic contouring function of EZ Sketch in Monaco (Elekta Inc.), a treatment planning system (TPS). ST_EZ3 was then duplicated and manually modified to create ST_MN. The CT data were reconstructed using Ziostation2 to create pelvic bone-only data, which were then imported into the TPS to create the structure using EZ Sketch. A 2-mm inner margin was added to create ST_Zio. Each structure was compared with ST_MN and evaluated using the Hausdorff distance (HD), mean distance to agreement (MDA), Dice similarity coefficient (DSC), and Jaccard similarity coefficient (JSC). Results: A comparison of ST_EZ1, ST_EZ3, and ST_Zio with ST_MN revealed the following: average HD, 53.87, 33.14, and 16.64, respectively; average MDA, 3.70, 2.03, and 0.99, respectively; average DSC, 0.80, 0.85, and 0.91, respectively; and average JSC, 0.68, 0.74, and 0.83, respectively. The average structure creation times were 1 min 7 s for ST_EZ1, 3 min 45 s for ST_EZ3, 1 min 50 s for ST_Zio, and 33 min 5 s for ST_MN. Conclusion: Diagnostic imaging workstations are effective for pelvic bone contouring, improving both efficiency and accuracy.

Indexed as

auto contouringdiagnostic imaging workstationradiotherapy

Identifiers

PMID41937879
PMCPMC13046410

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.