Evidence map›Paper›PMID 41937265›Full record

ArticleMedical physics2026

Evaluation of a water phantom detector-applicator setup for independent experimental verification of

Simon Dahlander, Michael Andrássy, Daniela Frömberg, Linda Persson, Åsa Carlsson Tedgren

Abstract readEvaluation Study
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Simon DahlanderDepartment of Oncology Pathology, Karolinska Institute, Stockholm, Sweden.
Michael AndrássyEckert & Ziegler BEBIG GmbH, Berlin, Germany.
Daniela FrömbergEckert & Ziegler BEBIG GmbH, Berlin, Germany.
Linda PerssonDepartment of Oncology Pathology, Karolinska Institute, Stockholm, Sweden.
Åsa Carlsson TedgrenDepartment of Oncology Pathology, Karolinska Institute, Stockholm, Sweden.

Funding

Swedish Cancer Foundation 24 0927 FKSwedish Cancer Foundation 24 3786 PJSwedish Radiation Safety Authority SSM2022-6507
6 · The paper itself

Abstract

backgroundPURPOSE: The BetaCheck-106™ is a prototype compact water phantom detector-applicator setup enabling high precision alignment of

methodsMeasurements were conducted on two

resultsThe BetaCheck-106™ demonstrated exceptional setup reproducibility (0.23%), enabling precise depth-resolved measurements. Both of the silicon diode detectors examined provided stable and reproducible measurements. The diamond detector performed reproducibly for the high-activity applicator but exhibited depth-dependent signal instability for the low-activity source, likely due to the detector's lower sensitivity. Normalized depth-signal curves for the three detectors all had similar shape. Analysis of measured current per activity of 20

conclusionsThe BetaCheck-106™ provides practical high-reproducibility positioning of detector and applicator for

Indexed as

BrachytherapyEye NeoplasmsPhantoms, ImagingRadiometryRuthenium RadioisotopesWaterHumansRadiotherapy DosageRuthenium-106Ruthenium RadioisotopesWaterdosimetryQARu‐106 brachytherapy

Identifiers

PMID41937265
PMCPMC13051029

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked