Evidence map›Paper›PMID 41935209›Full record

ArticleCardiovascular intervention and therapeutics2026

Influence of The Cusp-Overlap and three cusps coplanar techniques on new-onset conduction disturbances following transcatheter aortic valve implantation.

Léo Lemarchand, Raphael Grolleau, Dominique Boulmier, Guillaume Leurent, Jacques Tomasi, Abdelkader Bakhti, Sam Sharobeem, Maxime Nolf, Gwenaelle Sost, Marielle Le Guellec and 2 more

Abstract read
In one paragraph

Article in Cardiovascular intervention and therapeutics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Léo LemarchandCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Raphael GrolleauCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Dominique BoulmierCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Guillaume LeurentCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Jacques TomasiCHU Rennes Service de Chirurgie thoracique et cardio-vasculaire, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Abdelkader BakhtiCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Sam SharobeemCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Maxime NolfCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Gwenaelle SostService de gériatrie, CHU Rennes, Rennes, France.
Marielle Le GuellecCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Hervé Le BretonCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France.
Vincent AuffretCHU Rennes Service de Cardiologie, Université de Rennes 1, Inserm LTSI U1099, Rennes, F 35000, France. vincent.auffret@chu-rennes.fr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

New-onset conduction disturbances (NOCD) including high-degree atrioventricular block (HAVB), permanent pacemaker implantation (PPI) and new-onset left bundle branch block after transcatheter aortic valve implantation (TAVI) remain common and are influenced by implantation depth (ID) relative to patient-specific anatomy, particularly membranous septum length.To compare the cusp-overlap (COL) and conventional three-cusp coplanar (TCC) projection techniques with a focus on ID relative to membranous septum length and its association with conduction outcomes. A total of 501 patients undergoing TAVI with pre-procedural multidetector computed tomography were included. The primary endpoint was a composite of HAVB or PPI at 30 days. ID was measured on the final angiography. Propensity score overlap weighting analysis was performed to assess the effects of COL on ID and the main outcome.COL was significantly associated with higher valve implantation (ID 4.0 ± 1.95 mm vs. 5.54 ± 2.6 mm; β coefficient = -1.76; 95% CI: -2.24 to -1.26). The primary endpoint occurred at similar rates in both groups (15% vs. 19%; p = 0.24), and COL was not independently associated with the primary outcome (OR 0.63, 95% CI 0.36–1.12). Deeper implantation was associated with the primary outcome (4.66 ± 2.33 mm vs. 6.56 ± 2.66 mm; p < 0.01). A greater difference between membranous septum length and ID independently predicted lower event risk.COL was not independently associated with reduced NOCD but may facilitate higher implantation relative to membranous septum length, supporting an individualized, anatomy-guided implantation strategy.

Indexed as

Aortic ValveAortic Valve StenosisAtrioventricular BlockPostoperative ComplicationsTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansMaleMultidetector Computed TomographyRetrospective StudiesConduction disturbancesCusp-overlapImplantation depthMembranous SeptumTranscatheter Aortic Valve Implantation

Identifiers

PMID41935209
PMCPMC13279278

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.