ArticleAnnals of biomedical engineering2026
Physiological Load-Response in Synthetic Ligaments through Active Filament-Mixing Fabrication.
Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeAdditive manufacturing has enhanced medical trainers and their functionality, but synthetic tissues that are both anatomically accurate and capable of replicating musculoskeletal load responses remain largely unexplored. The purpose of this study is to demonstrate fabrication of synthetic tissue using active filament-mixing fabrication to enable local composition control with thermoplastic compositions tuned to match the modulus of elasticity of the respective tissues and functionally graded transitions between ligament and bone.
methodsSynthetic femoral anterior cruciate ligament (ACL) tibial complexes were fabricated and tested at 30° flexion along the tibial and anatomical load orientations matching the test procedure performed on cadaveric femoral ACL tibial complexes by Woo et al. in 1991. Load parameters were facilitated by section grips integrated into the design of test specimens without requiring a multi-axis jig.
resultsAnatomical accuracy was achieved by modeling tissues from magnetic resonance imaging data. Specimens loaded in the tibial orientation have an ultimate load of 287 ± 37 N and stiffness of 62.8 ± 11 N/mm. Specimens loaded in the anatomical orientation have an ultimate load of 312 ± 6.5 N and a stiffness of 43.5 ± 3.4 N/mm.
conclusionAlthough load response in the synthetic tissue was less than its cadaveric counterpart due to bending load from flexion, the methods of this study are versatile, repeatable, and compatible with a wide variety of printable thermoplastics and composites which can be applied to other tissues, joints, and load conditions.
Indexed as
Identifiers
41933249What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.