Evidence map›Paper›PMID 41931248›Full record

ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2026

Magnetic imprinted surface enhanced Raman scattering biosensor for the detection of bone loss biomarker CTX-I.

Diantao Zheng, Qiuyan Li, Ran Hu, Baoliang Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Diantao ZhengDepartment of Spine Surgery, Yongzhou Hospital Affiliated to Nanhua University, Yongzhou, 425000, Hunan, China.
Qiuyan LiDepartment of Spine Surgery, Yongzhou Hospital Affiliated to Nanhua University, Yongzhou, 425000, Hunan, China.
Ran HuCollege of Life Sciences and Technology, China Pharmaceutical University, Nanjing, China, 211198.
Baoliang ZhangDepartment of Spine Surgery, Yongzhou Hospital Affiliated to Nanhua University, Yongzhou, 425000, Hunan, China. b18674604575@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Serum C-terminal telopeptide of type I collagen (CTX-I) is a key bone turnover biomarker in osteoporosis, and its elevated levels are indicative of increased bone resorption. Current techniques for CTX-I measurement suffer from high operational requirements, complex procedures, and high costs. This study focuses on a novel strategy for detecting serum CTX-I concentration to predict the occurrence and severity of osteoporosis. Using silver-capped Fe3O4 (Fe3O4@Ag) as the substrate material, an artificial antibody for CTX-I was prepared via magnetic core-shell molecularly imprinted polymers (MIPs), and surface-enhanced Raman scattering (SERS) was used as a signal output device. With crystal violet (CV) at 10−4 M as the reporter molecule, the proposed biosensor exhibited a good linear response over the range of 10 pg/mL to 2 ng/mL (R2 = 0.986, LOQ = 4.79 pg/mL), covering the normal reference range required for identifying bone turnover. Moreover, the biosensing platform demonstrated resistance to matrix interference in real serum and urine samples. After six reuse cycles, the SERS intensity of CV decreased by only 10.5%, and after 15 days of storage at 4 °C, it decreased by 15.7%. The Fe3O4@Ag-MIPs were used to detect CTX-I with excellent uniformity (RSD = 4.1%) and repeatability (RSD = 2.7%), and the overall analysis time was 30 min. The proposed biosensing platform was applied to analyze known real serum samples obtained from human. The proposed biosensor was validated using enzyme-linked immunosorbent assay (ELISA), and the developed biosensor showed good correlation with ELISA. The experimental results indicate that the proposed novel biosensing platform is a fast, low-cost, and reliable tool for the rapid detection of the bone biomarker CTX-I in serum or urine.

Indexed as

Biosensing TechniquesCollagen Type IMolecular ImprintingOsteoporosisPeptidesSpectrum Analysis, RamanBiomarkersHumansSurface PropertiesBiomarkersCollagen Type Icollagen type I trimeric cross-linked peptidePeptidesBiosensingC-terminal telopeptide of type I collagenFe3O4@Ag-MIPsOsteoporosisSERS

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked