Evidence map›Paper›PMID 41930035›Full record

ArticleCureus2026

Ultrasound-Guided Superficial Temporal Artery Cannulation for Proximal Arterial Pressure Monitoring During Coarctation Repair With an Aberrant Right Subclavian Artery in a Low-Birth-Weight Neonate.

Masahiro Wakimoto, Motoi Kumagai, Kenji Suzuki

Abstract readCase Reports
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Masahiro WakimotoDepartment of Anesthesiology, Iwate Medical University Hospital, Yahaba, JPN.
Motoi KumagaiDepartment of Anesthesiology, Iwate Medical University Hospital, Yahaba, JPN.
Kenji SuzukiDepartment of Anesthesiology, Iwate Medical University Hospital, Yahaba, JPN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Coarctation of the aorta (CoA) complex with an aberrant right subclavian artery (ARSA) poses a significant challenge for intraoperative cerebral perfusion assessment because arterial pressure from both the upper and lower extremities becomes unreliable during aortic arch reconstruction. We report a 14-day-old male neonate weighing 1.819 kg with CoA complex, including patent ductus arteriosus (PDA), right-ventricle-type single ventricle, double-outlet right ventricle, single atrium, total anomalous pulmonary venous return (type IIa), mitral atresia, and ARSA, who underwent left subclavian artery flap aortoplasty, PDA clipping, and pulmonary artery banding. Because both subclavian and descending aortic circulations were expected to be unreliable during aortic cross-clamping, the superficial temporal artery (STA) was selected as the only feasible site for real-time cerebral perfusion monitoring. Preoperative ultrasound revealed an extremely small STA (0.47×0.35 mm), yet ultrasound-guided cannulation using a high-frequency linear probe enabled the successful placement of a 24-gauge catheter and provided stable arterial waveforms throughout the procedure. This allowed continuous assessment of cerebral perfusion during aortic cross-clamping and confirmation of the absence of residual pressure gradients after repair. Postoperatively, the patient required diaphragmatic plication for phrenic nerve palsy but otherwise recovered satisfactorily. This case illustrates that ultrasound-guided STA cannulation can be an effective and feasible monitoring option in low-birth-weight infants with complex cardiac anatomy when conventional arterial sites are not usable.

Indexed as

aberrant right subclavian arteryaortic cross-clampingcerebral perfusion monitoringcoarctation of the aortacomplex congenital heart diseaselow-birth-weight neonateneonatal arterial linesubclavian flap aortoplastysuperficial temporal arteryultrasound-guided cannulation

Identifiers

PMID41930035
PMCPMC13041093

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.