Evidence map›Paper›PMID 41927624›Full record

ArticleScientific reports2026

Validation of the inferior vena cava collapsibility as a predictive marker of fluid responsiveness in spontaneously breathing patients.

Benoît Ter Schiphorst, Claire Bourel, Arthur Durand, Camille Ternynck, Thierry Onimus, Michael Howsam, Alexandre Pierre, Julien De Jonckheere, Raphael Favory, Sebastien Preau

Registry-linked trialAbstract readValidation Study
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03780660 (Diagnostic Accuracy of the Central Venous Pressure), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03780660 completednot on this map

Diagnostic Accuracy of the Central Venous Pressure (CVP) Variation to Predict Fluid Responsiveness in Spontaneously Breathing Patients

TypeobservationalSponsorUniversity Hospital, LilleRan2019 to 2021Enrolled68ConditionsBreathing
3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Benoît Ter SchiphorstIntensive Care Department, CHU Lille, Lille, France.
Claire BourelIntensive Care Department, CHU Lille, Lille, France.
Arthur DurandIntensive Care Department, CHU Lille, Lille, France.
Camille TernynckDepartment of Biostatistics, CHU Lille, Lille, France.
Thierry OnimusIntensive Care Department, CHU Lille, Lille, France.
Michael HowsamUniv. Lille, INSERM UMR 1167 RID-AGE, Lille, France.
Alexandre PierreIntensive Care Department, CHU Lille, Lille, France.
Julien De JonckheereCHU Lille, INSERM CIC-IT 1403, Lille, France.
Raphael FavoryIntensive Care Department, CHU Lille, Lille, France.
Sebastien PreauIntensive Care Department, CHU Lille, Lille, France. seb.preau@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In a previous derivation cohort, we found that inferior vena cava collapsibility (cIVC) thresholds of ≥ 33% during non-standardised breathing (cIVC-ns) and ≥ 44% during a standardised breathing manoeuvre (cIVC-st) identified fluid responsiveness (FR). The aim of this study was to validate these findings through a secondary analysis of a prospective validation cohort. We measured cIVC-ns and cIVC-st in spontaneously breathing adult patients in a sub-xiphoid, long-axis view, using the two-dimensional mode, at 4 cm from the cavo-atrial junction. An increase in the subaortic time-velocity integral during a passive leg raising test (∆VTI) ≥ 10% was used to define FR. Among 61 intensive care unit (ICU) patients included, a cIVC-ns ≥ 33% predicted FR with a sensitivity and a specificity of 84% and 83%, respectively. A cIVC-st ≥ 44% predicted FR with a sensitivity and a specificity of 94% and 87%, respectively. A cIVC-ns ≥ 33% and a cIVC-st ≥ 44% misclassified 16.4% and 8.2% of the patients respectively (p = 0.06). Measuring cIVC is a reliable, non-invasive tool to predict FR in pontaneously breathing patients admitted to ICU. However, the clinical added value of a standardised breathing manoeuvre to improve its diagnostic accuracy warrants further investigation in dedicated studies.Trial registration: Name of the registry: Diagnostic Accuracy of the Central Venous Pressure (CVP) Variation to Predict Fluid Responsiveness in Spontaneously Breathing Patients (VPVC). Trial registration number: NCT03780660.

Indexed as

Fluid TherapyRespirationVena Cava, InferiorAgedFemaleHumansIntensive Care UnitsMaleMiddle AgedProspective StudiesCollapsibility indexFluid responsivenessInferior vena cavaPassive leg raisingPreload responsivenessSpontaneous breathing

Identifiers

PMID41927624
PMCPMC13187124

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.