Evidence map›Paper›PMID 41923520›Full record

ArticleAdvanced healthcare materials2026

Enhanced Endoscopic Internal Drainage of Gastric Abscess Through Additively Manufactured Stents.

Parima Phowarasoontorn, Yongbin Ko, Juan S Barajas-Gamboa, Juan P Pantoja, Oraib Al-Ketan, Mohamed Ali, Sungyun Sohn, Heba Tageldeen Naser, Abdel-Hameed Dabbour, Batoul Khlaifat and 5 more

Abstract read
In one paragraph

Article in Advanced healthcare materials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Parima PhowarasoontornDivision of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.
Yongbin KoDivision of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.
Juan S Barajas-GamboaDigestive Disease Institute, Department of General Surgery, Cleveland Clinic Abu Dhabi, Abu Dhabi, UAE.
Juan P PantojaDigestive Disease Institute, Department of General Surgery, Cleveland Clinic Abu Dhabi, Abu Dhabi, UAE.
Oraib Al-KetanCore Technology Platform, New York University Abu Dhabi, Abu Dhabi, UAE.
Mohamed AliDivision of Science, New York University Abu Dhabi, Abu Dhabi, UAE.
Sungyun SohnDivision of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.
Heba Tageldeen NaserDivision of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.
Abdel-Hameed DabbourDivision of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.
Batoul KhlaifatDivision of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.
Ahmed AlZubaidiDigestive Disease Institute, Department of General Surgery, Cleveland Clinic Abu Dhabi, Abu Dhabi, UAE.
Carlos Abril VegaDigestive Disease Institute, Department of General Surgery, Cleveland Clinic Abu Dhabi, Abu Dhabi, UAE.
John RodriguezDigestive Disease Institute, Department of General Surgery, Cleveland Clinic Abu Dhabi, Abu Dhabi, UAE.
Matthew KrohDigestive Disease and Surgery Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Khalil B RamadiDivision of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE.ORCID https://orcid.org/0000-0002-5864-2386

Funding

New York University Abu DhabiSandooq Al Watan F22-016
6 · The paper itself

Abstract

Postoperative gastric leaks (GL), a serious complication of bariatric surgery, are often managed by endoscopic internal drainage using biliary double-pigtail stents (DPS). However, conventional extruded thermoplastic (e.g., polyethylene, polyurethane, and polytetrafluoroethylene) stents often provide inadequate drainage, suboptimal anatomical conformity, and are prone to migration, collectively hindering patient recovery and contributing to an adverse event rate of 13.8%. To address these limitations, we developed PETALS (Personalized Endoscopic Transmural Abscess Leak Solution), an analytical framework for the optimization of stent designs dedicated to transmural fluid drainage. We identified stent length and diameter as critical geometric parameters influencing fluid dynamics. Using PETALS, we designed a family of stents with longitudinal fins fabricated by stereolithography (SLA) using Formlabs Flexible 80A resin. The Lily design, a six-segment PETALS construct, achieved a 32% reduction in hydraulic resistance and a 30% increase in flow rate compared with a commercial DPS in a benchtop GL model, while also exhibiting superior flexibility. PETALS thus enables the fabrication of patient-specific, additively manufactured stents with increased flow rate, potentially reducing complications and shortening hospitalization.

Indexed as

AbscessDrainageStentsHumans3D printinganastomotic leaksbariatric surgerycomputational fluid dynamics (CFD)stents

Identifiers

PMID41923520
PMCPMC13241474

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.