Evidence map›Paper›PMID 41923225›Full record

ArticleBMC oral health2026

Tooth rotational control with varying attachment configurations in clear aligners under compromised periodontal ligament support: a finite element study.

Yuching Huang, HiuChing Wong, Pu Yang

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yuching HuangState Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, China.
HiuChing WongState Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, China.
Pu YangState Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, China. yangpu@scu.edu.cn.

Funding

APAC Align Research Award AQKY22-1-4China Oral Health Foundation A2021-143
6 · The paper itself

Abstract

backgroundWith the high prevalence of periodontitis, tooth rotation resulting from periodontal damage can be corrected through orthodontic treatment; however, the biomechanical complexity of tooth movement in compromised periodontal tissues, combined with the inherently low rotation accuracy of clear aligners, present significant challenges to tooth rotational control. This finite element study aimed to explore appropriate attachment configurations for tooth rotation under periodontally compromised conditions.

methodsBased on cone beam computed tomography data of a patient, three-dimensional finite element models of the upper dental arch, periodontal ligament (PDL), alveolar bone, aligners, and attachments were created. The right maxillary second premolar(A5) was targeted as the rotated tooth with a 30°clockwise rotation. Simulations were conducted with varying alveolar bone loss levels (0/2/4/6 mm) and attachment configurations (none, vertical/horizontal rectangular, and vertical elliptical). A 1° aligner activation angle was applied, and finite element analysis was performed for 16 conditions to assess tooth displacement, periodontal ligament stress, and aligner condition by Ansys Workbench.

resultsAll groups achieved counterclockwise rotation of the A5, but exhibited concomitant tipping and intrusion. PDL von Mises stress peaked in the lingual cervical region and exceeded apical values. The vertical ellipsoid attachment produced the greatest rotational displacement and highest cervical periodontal ligament stress. The horizontal rectangular attachment showed a more favorable center of rotation with comparatively large rotational displacement and cervical periodontal ligament stress. The vertical rectangular attachment yielded lower cervical periodontal ligament stress and reduced anchorage loss, but smaller rotational displacement and more pronounced undesired displacement. Increasing alveolar bone loss shifted the center of rotation and increased displacement, accompanied by greater undesired biomechanical effects, anchorage loss, and periodontal ligament stress.

conclusionsThe horizontal rectangular attachment showed a condition-specific mechanical trade-off within this framework; therefore, clinical extrapolation should be cautious and supported by patient-specific in vivo validation. Treatment planning for rotational movements should consider periodontal support, with close periodontal monitoring and biomechanically informed attachment selection to reduce unintended movements and periodontal loading.

Indexed as

Finite Element AnalysisPeriodontal LigamentTooth Movement TechniquesAlveolar Bone LossBicuspidBiomechanical PhenomenaCone-Beam Computed TomographyHumansImaging, Three-DimensionalRotationAlveolar bone lossAttachmentsClear alignersFinite element analysisPeriodontal damageTooth rotation

Identifiers

PMID41923225
PMCPMC13122910

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.