Evidence map›Paper›PMID 41923100›Full record

ArticleBMC oral health2026

Material jetting-based fabrication of a modified zirconia implant-supported crown: evaluation of dimensional accuracy in vitro.

Zewen Mou, Ruifeng Li, Zehao Pan, Xuri Guo, Yaxuan Huang, Jiang Li, Ping Li, Jiangyong Huang

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zewen Mou *School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China.
Ruifeng Li *School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China.
Zehao PanSchool and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China.
Xuri GuoSchool and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China.
Yaxuan HuangSchool and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China.
Jiang LiSchool and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China.
Ping LiSchool and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China. pingli@gzhmu.edu.cn.
Jiangyong HuangSchool and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China. JYHuang@gzhmu.edu.cn.

Funding

Key Clinical Technique of Guangzhou Municipal Health Commission 2023C-ZD07Plan on Enhancing Scientific Research in GMU GMUCR2024-02023
6 · The paper itself

Abstract

backgroundThe dimensional accuracy and fit of zirconia implant-supported crowns fabricated using material jetting (MJ) technology remain unclear, particularly at critical intaglio interfaces. This study compared the accuracy of a modified implant-supported crown fabricated by MJ and subtractive manufacturing (SM).

methodsA modified implant-supported crown structure was designed and fabricated using MJ (Carmel 1400 C, Xjet) and SM techniques (n = 12 crowns and 12 inlays per group). Three intaglio regions were analyzed: the inlay intaglio surface (IIS), crown–inlay contact surface (CIS), and crown–abutment contact surface (CAS). Specimens were scanned, aligned to CAD references via best-fit in 3D inspection software, and assessed for trueness and precision. Trueness was analyzed using independent t-tests (α = 0.05), and intraclass correlation coefficient (ICC) was used to assess the agreement of precision.

resultsMJ exhibited significantly higher trueness than SM in all regions (p < 0.05), with the largest difference observed in the CIS region. All MJ samples remained within the clinical threshold (< 120 μm), while SM exceeded it in CIS (203.08 μm). ICC analysis showed low agreement in precision between MJ and SM. SM restorations exhibited seating interference, whereas MJ restorations achieved complete seating with good adaptation.

conclusionsMJ technology achieved high dimensional accuracy in implant-supported crowns with complex structures, outperforming SM in critical regions. Besides RMS values, maximum deviations in key contact areas are also clinically important, as excessive peaks may cause seating interference.

Indexed as

CrownsDental MaterialsDental Prosthesis DesignDental Prosthesis, Implant-SupportedZirconiumComputer-Aided DesignHumansIn Vitro TechniquesSurface PropertiesDental MaterialsZirconiumzirconium oxideAdditive manufacturingDimensional accuracyMaterial jettingTruenessZirconia crown

Identifiers

PMID41923100
PMCPMC13170152

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.