Evidence map›Paper›PMID 41921102›Full record

ArticleActa orthopaedica2026

Long-term implant retention after impacted elastic stable intramedullary nailing in pediatric diaphyseal forearm fractures: a retrospective cohort study.

Jan Egil Brattgjerd, Christer Aasheim, Astrid Rosenberg, Christoffer Fotland, Vera Halvorsen

Abstract read
In one paragraph

Article in Acta orthopaedica, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jan Egil BrattgjerdDivision of Orthopaedic Surgery, Oslo University Hospital, Oslo; Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo; Institute of Rehabilitation Science and Health Technology, Faculty of Health Science, Oslo Metropolitan University, Oslo, Norway. jbratt@ous-hf.no.ORCID 0000-0002-9266-129X
Christer AasheimDivision of Orthopaedic Surgery, Oslo University Hospital, Oslo; Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway.
Astrid RosenbergDivision of Orthopaedic Surgery, Oslo University Hospital, Oslo; Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway.
Christoffer FotlandDivision of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.
Vera HalvorsenDivision of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeIn elastic stable intramedullary nailing (ESIN) for forearm fractures, nail protrusion may cause irritation-related implant removal. The primary aim was to evaluate implant retention after nail impaction, and secondarily to assess secondary procedures, complications, and protrusion as a predictor of removal.

methodsWe analyzed a retrospective cohort of children with diaphyseal forearm fractures treated with impacted ESIN between 2017 and 2024. Implant retention was defined as no nail removal at record review. Secondary procedures were unplanned operations, while complications were adverse events managed conservatively. Radiographic nail protrusion was measured as extraosseous nail length and evaluated using receiver operating characteristic analysis to predict irritation-related implant removal.

results160 children with diaphyseal forearm fractures were included. At a mean observation time of 5 years, 132/160 children retained their implants (83%, 95% confidence interval [CI] 76-88). Secondary procedures occurred in 30/160 patients (19%, CI 13-26), most commonly irritation-related implant removal (10%, CI 6-16) and refracture (6%, CI 3-10). Complications occurred in 19/160 patients (12%, CI 7-18), including superficial radial nerve symptoms (7/160; 4.4%) and irritation without implant removal (6/160; 3.8%). A protrusion threshold of 3.3 mm predicted irritation-related implant removal (AUC 0.79, CI 0.71-0.86; sensitivity 100%, CI 83-100; specificity 55%, CI 49-61). No irritation-related removals occurred below this threshold.

conclusionImpacted ESIN was associated with high long-term implant retention, although secondary procedures and complications occurred in about one-third of the patients. A protrusion threshold of 3 mm was linked to irritation-related removal and may guide implant retention.

Indexed as

Bone NailsFracture Fixation, IntramedullaryRadius FracturesUlna FracturesAdolescentChildChild, PreschoolDiaphysesFemaleHardware RemovalHumansMalePostoperative ComplicationsRetrospective Studies

Identifiers

PMID41921102
PMCPMC13044701

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.