ArticleFrontiers in medicine2026
24-hour urinary total protein quantitative detection for pregnant women with unit conversion failure: a case report and laboratory administration reflection.
Article in Frontiers in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Analogous to medication dosage errors, inaccuracies in measurement units for analyte test results in clinical laboratories can lead to adverse clinical consequences. We report a case of a 35-years-old pregnant woman at 38 weeks of gestation with a history of gestational hypertension. During routine follow-up, she presented with elevated blood pressure, abnormal qualitative urinary protein findings, and an elevated random urinary protein concentration, prompting a request for 24-hour urinary total protein quantification (UTP). The laboratory reported her 24-hour urine total protein excretion as 547.87 g/24 h, which the attending physician identified as inconsistent with the patient's clinical manifestations. Unfortunately, the medical laboratory professional failed to identify the cause of the discrepancy following receipt of the feedback and only reported the issue to the laboratory quality supervisor 1 week later. In the detection system, both the direct and 1:2 auto-diluted measurements triggered an "F" alarm code, indicating the analyte concentration exceeded the analytical measurement range. When the alarm code in the data flag column and the analyte measurement result were simultaneously transmitted to the Laboratory Information System (LIS), precluding accurate data recognition and extraction by the LIS. This led to the appearance of the alarm code in the LIS result field and disrupted the automatic unit conversion process. According to relevant requirements (such as those in the detection system operation manual or the laboratory-developed standard operating procedure), if the alarm code appears in the data flag column of the measurement result, it is necessary to further increase the dilution ratio and conduct a re-measurement. Regrettably, the alarm code was mishandled in the laboratory: it was manually suppressed in the LIS. This resulted in the failure of the automatic unit conversion, leading to a 100-fold overestimation as the results were erroneously reported in "g/L" instead of mg/dL." This case highlights critical quality management considerations for other clinical laboratories, emphasizing the importance of unit consistency across diverse detection platforms and information systems, and the quality risks associated with falsely decreased results when analyzing high-concentration samples.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.