Evidence map›Paper›PMID 41919030›Full record

ArticleJournal of the Society for Cardiovascular Angiography & Interventions2026

Transseptal Device Comparison for Improved Puncture and Streamlined Mitral Edge-To-Edge Repair.

Anastasia E I Malek, Meghali Singhal, Wes Soliman, Saja Al-Dujaili, Mohammad Al-Khalaf, Brynn Okeson, Carmen Carbajal, Samantha Yim, Jason Boyatt, David Lerner and 2 more

Abstract read
In one paragraph

Article in Journal of the Society for Cardiovascular Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Anastasia E I MalekSanta Barbara Cottage Hospital, Santa Barbara, California.
Meghali SinghalSanta Barbara Cottage Hospital, Santa Barbara, California.
Wes SolimanSanta Barbara Cottage Hospital, Santa Barbara, California.
Saja Al-DujailiDepartment of Scientific Affairs, Access Solutions, Boston Scientific Corporation, Mississauga, Ontario, Canada.
Mohammad Al-KhalafDepartment of Scientific Affairs, Access Solutions, Boston Scientific Corporation, Mississauga, Ontario, Canada.
Brynn OkesonBoston Scientific Corporation, Marlborough, Massachusetts.
Carmen CarbajalSanta Barbara Cottage Hospital, Santa Barbara, California.
Samantha YimSanta Barbara Cottage Hospital, Santa Barbara, California.
Jason BoyattSanta Barbara Cottage Hospital, Santa Barbara, California.
David LernerSansum Clinic, Santa Barbara, California.
Michael ShenodaSanta Barbara Cottage Hospital, Santa Barbara, California.
Joseph AragonSanta Barbara Cottage Hospital, Santa Barbara, California.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Septal anatomy dictates the complexity of transseptal puncture (TSP) and strongly influences left atrial access for large mitral transcatheter edge-to-edge mitral valve repair. This study aimed to compare 2 TSP needle-based techniques-mechanical needle (MN; BRK Transseptal Needle, Abbott) and radiofrequency-powered needle (RFN; NRG Transseptal Needle, Boston Scientific)-with the VersaCross Large Access system (VLA, Boston Scientific), comprising a radiofrequency wire and 12.5F transseptal introducer. Methods: This is a retrospective single-center review of consecutive MitraClip (Abbott) cases using MN (n = 28), RFN (n = 55)-both with an 8.5F sheath and pigtail exchange wire, and VLA (n = 109). Procedures were evaluated for TSP success, time to TSP, MitraClip steerable guide catheter (SGC) delivery, clip deployment, and overall procedure time. Acute adverse events were assessed. Results: The TSP was successful in 100% of cases with no adverse events. The TSP time from groin access was the shortest with VLA (MN, 26.6 ± 18.5 minutes; RFN, 21.3 ± 11.9 minutes; VLA, 15.8 ± 10.0 minutes). VLA required less time to SGC delivery from TSP (MN, 18.4 ± 12.8 minutes; RFN, 9.7 ± 5.1 minutes; VLA, 5.4 ± 4.6 minutes). There were no differences in time to clip deployment between groups. Total procedure time was the lowest with VLA (MN, 138 ± 64 minutes; RFN, 123 ± 63 minutes; VLA, 96 ± 51 minutes). TSP and SGC delivery times were more consistent using VLA than those with MN ( Conclusions: Use of VLA allowed for shorter TSP times and more efficient SGC delivery into the left atrium. The choice of transseptal technique can improve overall procedure time, leading to catheterization laboratory predictability and efficiency.

Indexed as

MitraCliptranscatheter repairtransseptal punctureVersaCross

Identifiers

PMID41919030
PMCPMC13033766

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.