Evidence map›Paper›PMID 41918705›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Are continuous locking headless bone screws with locking plate fixation effective for bridging fracture gaps in far cortical locking constructs? An in vitro biomechanical and finite element study under simplified axial loading.

Chen-Chiang Lin, Ya-Han Chan, Po-Feng Su

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chen-Chiang LinDepartment of Orthopedics, National Taiwan University Hospital Yun-Lin Branch, Douliou, Yunlin, Taiwan.
Ya-Han ChanDepartment of Biomedical Engineering, National Yang Ming Chaio Tung University, Hsinchu, Taiwan.
Po-Feng SuDepartment of Orthopedics, Changhua Christian Hospital, Changhua, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Locking screws typically provide more stable fixation than conventional cortical screws. However, the rigid connection between the locking screw head and plate hole can cause stress concentrations and lead to early failure under cyclic loading. This study aimed to compare the mechanical stability of a continuous (headless) locking screw with standard locking screws and cortical screws, either in a standard (flush with the bone) or in far cortical locking constructs, using biomechanical testing and finite element analysis (FEA). Methods: The Trident Distal Radial Locking Plate (A-Plus Biotechnology Co., Ltd., Taiwan) was used to repair a simulated distal radial diaphysis fracture and was secured to the bone using different screw types. The fracture gap was bridged with the plate placed flush with the bone and with the plate offset from the bone surface by 4 mm (far cortical locking (FCL)). The constructs were subjected to static compression and cyclic axial loading tests to assess construct stiffness and yield load, as well as endurance and failure mechanisms under cyclic loading, while FEA was used to evaluate the von Mises stress distribution on the plates and screws. Results: The Group 3a (flush with bone, continuous locking screws) had a significantly higher yield load than Groups 2b (FCL with locking screws) and 3b (FCL with continuous locking screws) (p < 0.05). In addition, Group 1 (flush with bone, cortical screws) was found to be significantly stiffer than Groups 2b and 3b (p < 0.01). For the dynamic testing, Group 3a showed intermediate endurance and failed predominantly by screw pull-out, whereas Groups 1 and 2 primarily failed by plate deformation. The FEA results showed stress concentrations at the screw neck of the standard locking screws and around the threaded regions of the continuous locking screws. Conclusion: Continuous locking screws placed flush with the bone had the greatest fixation strength of all configurations tested. However, using continuous locking screws in an FCL configuration may redirect stress to the threaded region of the screw neck, potentially increasing the risk of failure.

Indexed as

biomechanical testbone fracturefar cortical locking constructsheadless bone screwlocking plate fixation

Identifiers

PMID41918705
PMCPMC13033729

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.