Evidence map›Paper›PMID 41918556›Full record

ArticleIndoor environments2025

Rethinking heat in thousands of school classrooms through continuous monitoring and novel exposure metrics.

M Pilar Botana Martinez, Priam Dinesh Vyas, Katherine H Walsh, Lauren Main, Lauren Bolton, Yirong Yuan, Masanao Yajima, M Patricia Fabian

Abstract read
In one paragraph

Article in Indoor environments, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

M Pilar Botana MartinezDepartment of Environmental Health, Boston University School of Public Health, 715 Albany Street, Talbot Building 4th floor West, Boston, MA 02118, United States.
Priam Dinesh VyasDepartment of Environmental Health, Boston University School of Public Health, 715 Albany Street, Talbot Building 4th floor West, Boston, MA 02118, United States.
Katherine H WalshBoston Public Schools, 2300 Washington St, Roxbury, Boston, MA 02119, United States.
Lauren MainBoston Public Schools, 2300 Washington St, Roxbury, Boston, MA 02119, United States.
Lauren BoltonBoston Public Schools, 2300 Washington St, Roxbury, Boston, MA 02119, United States.
Yirong YuanDepartment of Environmental Health, Boston University School of Public Health, 715 Albany Street, Talbot Building 4th floor West, Boston, MA 02118, United States.
Masanao YajimaDepartment of Mathematics and Statistics, Boston University, 665 Commonwealth Ave, Boston, MA 02215, United States.
M Patricia FabianDepartment of Environmental Health, Boston University School of Public Health, 715 Albany Street, Talbot Building 4th floor West, Boston, MA 02118, United States.

Funding

Environmental Epidemiology in Community SettingsT32ES014562 · NIEHS · BOSTON UNIVERSITY MEDICAL CAMPUS · PI Birgit Gunhild Claus Henn · 2006 to 2026
$7.7M
Asthma Simulation Tool for Housing, Medication and Social Adversity (ASTHMA)R01ES027816 · NIEHS · BOSTON UNIVERSITY MEDICAL CAMPUS · PI FABIAN, MARIA PATRICIA · 2017 to 2021
$2.4M
NIEHS NIH HHS R01 ES027816NIEHS NIH HHS T32 ES014562
6 · The paper itself

Abstract

As global temperatures rise, heat exposure in classrooms is becoming a growing concern for the millions of students attending school, in particular those learning in buildings without air conditioning (AC). With limited resources and competing interests, school decision-makers need health-related data-based approaches to inform cooling solutions and prioritize investments. In collaboration with a large school district in Northeastern United States (US), we analyzed minute-level temperature data in > 3600 classrooms across 125 school buildings during the 2023 hot season. Using a first-of-its-kind commercial-grade indoor sensor network and data science methods, we quantified heat exposure through novel heat metrics capturing intensity, frequency, and duration, and characterized spatial variability within and across buildings with three types of AC. On average, intra-building temperature variability was 2.3 degrees Celsius (°C), with a maximum value of 14.3°C. On a hot day, classrooms exceeded extreme caution thresholds by 0.1 %, 1.1 %, and 8.4 % in schools with central, window, and no AC, respectively. Classrooms on the top floor were 0.3°C, 0.5°C, and 5.7°C warmer than classrooms on the first floor, for central, window, and no AC groups, respectively. Novel and traditional heat exposure metrics were weakly correlated, with implications for school rankings. Findings identified schools with the greatest cooling needs and investigated key predictors of classroom overheating. Our results underscore the need for continuous temperature monitoring in all classrooms and highlight the importance of access to mechanical cooling in locations that have historically not been prepared for extreme heat. Our work shows how data analyses informed by researcher-school partnerships can support critical climate resilience needs in schools.

Indexed as

Climate resilienceExtreme heatHeat exposureIndoor environmental quality monitoringSchoolsTemperature

Identifiers

PMID41918556
PMCPMC13035369

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.