Evidence map›Paper›PMID 41918061›Full record

ArticleJournal of Indian Prosthodontic Society2026

Material-dependent trueness of intraoral scanners: A comparative analysis of three scanning technologies for different crowns - An in vitro study.

Meghna Budati, Subhabrata Maiti, Jessy Paulraj

Abstract readComparative Study
In one paragraph

Article in Journal of Indian Prosthodontic Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Meghna BudatiDepartment of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
Subhabrata MaitiDepartment of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
Jessy PaulrajDepartment of Pedodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThe aim of this was to assess and compare the accuracy of three intraoral scanners (IOS) under clinical conditions-active triangulation (Medit i700), parallel confocal (3Shape TRIOS), and optical triangulation (Primescan) by comparing their root mean square (RMS) deviation and maximum deviations to a high-accuracy reference scan using the 3Shape E4 extraoral scanner across six different crown material substrates. SETTINGS AND

designThe study was conducted in an in vitro setting, comparing different IOS technologies. MATERIALS AND

methodsAn in vitro study was performed using a three-dimensional (3D)-printed maxillary model with crowns fabricated from lithium disilicate ceramic (Emax), layered zirconia, monolithic zirconia, cobalt-chromium alloy, Polyetheretherketone (Bio-HPP), and Polyetherketoneketone (Pekkton). Each IOS performed 24 scans of the crowns following device-specific protocols. Accuracy was assessed by superimposing scans with the reference using Geomagic Control X software (Version 2020.0.1, 3D Systems, Rock Hill, SC, USA) to determine RMS and maximum deviations. STATISTICAL ANALYSIS USED: Scanning accuracy among devices and materials was evaluated using one-way analysis of variance with Tukey post hoc tests. P < 0.05 was considered to be statistically significant.

resultsOptical triangulation demonstrated the highest trueness for most materials, with the lowest RMS deviations for Emax (0.031 ± 0.003 mm), Bio-HPP (0.034 ± 0.002 mm), and Pekkton (0.035 ± 0.002 mm). Active triangulation performed best for the reflective cobalt-chromium alloy (0.183 ± 0.256 mm). There were significant differences seen in the accuracy of scanners and materials (P < 0.05).

conclusionIOS trueness is influenced by substrate material and scanner technology. Optical triangulation excelled with translucent and low-reflective materials, whereas active triangulation showed superior performance with the reflective substrates. Material-specific scanning protocols are critical for achieving optimal clinical outcomes.

Indexed as

CrownsBenzophenonesComputer-Aided DesignDental Prosthesis DesignHumansIn Vitro TechniquesPrinting, Three-DimensionalZirconiumBenzophenonesZirconiumzirconium oxideAccuracyactive triangulationintraoral scannersoptical triangulationparallel confocaltrueness

Identifiers

PMID41918061
PMCPMC13118157

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.