Development of a high-precision evaluation system for radial pulse wave applanation tonometry devices.

Min-Ho Jun, Seunghwan Choy, Young-Min Kim

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Min-Ho JunDigital Health Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon, 34054, Republic of Korea.
Seunghwan ChoyDigital Health Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon, 34054, Republic of Korea.
Young-Min KimR&D Strategy Division, Korea Institute of Oriental Medicine (KIOM), 1672 Yuseongdaero, Yuseong-gu, Daejeon, 34054, Republic of Korea. irobo77@kiom.re.kr.

Funding

Korea Institute of Oriental Medicine (KIOM) KSN2512012Ministry of Food and Drug Safety 21174MFDS225
6 · The paper itself

Abstract

The demand for wearable devices for daily health management and tonometry-based pulse wave measurement has grown rapidly. However, the absence of standardized and physiologically realistic evaluation systems remains a major barrier to developing reliable and clinically applicable devices. Although ISO 18615:2020 defines general performance requirements for electronic radial pulse tonometric devices, no evaluation platform has been available to assess these standards with higher precision. We developed a novel high-precision evaluation system that integrates a 3D cam-based pulse wave generation unit, wrist simulation unit, system control unit, and applied pressure unit. This platform enables controlled and reproducible simulation of physiological pulse waves, including variations in base pressure, pulse pressure, applied pressure, and radial skin and arterial properties, which have been difficult to replicate in previous systems. The system was designed not only to meet but also to exceed ISO 18,615 requirements, thereby enabling precise performance assessment. Validation experiments evaluated pulse wave precision and range, as well as artificial radial artery characteristics. The system demonstrated high reproducibility and accuracy. The mean coefficients of variation (CVs) were 0.29% for applied pressure, 0.11% for pulse waves, and 0.05% for pulse rate. The CVs of pulse wave shape parameters H and T were 1.06% and 1.60%, respectively. The systole/diastole ratio (SDR) ranged from 24.45% to 57.69% with a 1.04% error ratio, the pulse rate from 19.93 bpm to 204.90 bpm with a 0.34% error ratio, and the base pressure from − 3.17 mmHg to 116.51 mmHg with a 3.60% error ratio. This study presents the first comprehensive evaluation platform capable of reproducing physiologically realistic radial arterial pulse waves with high precision and reproducibility. By referencing and surpassing ISO 18,615 performance requirements, the system provides rigorous and reliable assessment of device performance. This platform reduces variability, enables precise calibration, and offers a benchmark for evaluating tonometry-based and wearable pulse wave measurement devices. It is expected to accelerate the development of high-quality cardiovascular monitoring technologies and support the clinical translation of wearable health monitoring devices.

Indexed as

Applanation tonometry devicesArtificial radial arteryPrecise pulse simulatorPulse wave evaluation systemRadial artery pulse wave

Identifiers

PMID41917145
PMCPMC13187050

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.