Evidence map›Paper›PMID 41915368›Full record

ArticleInternational journal of implant dentistry2026

Accuracy of dynamic computer-assisted implant surgery among novice operators using three different patient registration methods: an in-vitro study.

Ryo Yamamoto, Toshiki Nojiri, Daichi Yoshida, Yutaro Oyamada, Akihiro Fukutoku, Kazuhiro Kon

Abstract read
In one paragraph

Article in International journal of implant dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ryo YamamotoDivision of Fixed Prosthodontics and Oral Implantology, Department of Prosthodontics, School of Dentistry, Iwate Medical University, Morioka, Japan.
Toshiki NojiriDivision of Fixed Prosthodontics and Oral Implantology, Department of Prosthodontics, School of Dentistry, Iwate Medical University, Morioka, Japan. toshikin@iwate-med.ac.jp.
Daichi YoshidaDivision of Fixed Prosthodontics and Oral Implantology, Department of Prosthodontics, School of Dentistry, Iwate Medical University, Morioka, Japan.
Yutaro OyamadaDivision of Fixed Prosthodontics and Oral Implantology, Department of Prosthodontics, School of Dentistry, Iwate Medical University, Morioka, Japan.
Akihiro FukutokuDivision of Fixed Prosthodontics and Oral Implantology, Department of Prosthodontics, School of Dentistry, Iwate Medical University, Morioka, Japan.
Kazuhiro KonDivision of Fixed Prosthodontics and Oral Implantology, Department of Prosthodontics, School of Dentistry, Iwate Medical University, Morioka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAccurate implant placement with computer-assisted implant surgery (CAIS) is critical to ensuring long-term success. Dynamic computer-assisted implant surgery (d-CAIS) enhances surgical precision through real-time feedback; however, its accuracy and procedural efficiency when used by novice operators remain insufficiently investigated. This study evaluated how different registration methods in d-CAIS influence implant placement accuracy and procedural time when performed by novice operators. MATERIALS AND

methodsIn this in vitro study, three registration methods were assessed (surface-based registration: ND, marker-based registration: XC, and pair-point registration: XM groups). Five novice operators, defined as dentists with less than five years of implant experience, placed 25 implants per group (75 total) in partially edentulous maxillary models. Postoperative cone-beam computed tomography scans were used to measure deviations at the implant entry point, apex, vertical depth, and angle. Statistical analyses were performed to compare group differences.

resultsMean three-dimensional deviations at the implant entry point were 0.97 mm (ND), 0.68 mm (XC), and 0.72 mm (XM); at the apex: 1.33 mm, 0.78 mm, and 0.90 mm, respectively. Vertical depth deviations at the apex were comparable across groups: 0.62 mm (ND), 0.51 mm (XC), and 0.54 mm (XM). Angular deviation was highest in the ND group (3.16°) compared to the XC (1.18°) and XM (0.97°) groups, with significant differences observed between ND and both XC and XM. Average procedural time was longest in the ND group and shortest in the XM group, with statistically significant differences between ND and the other two groups.

conclusionsIn novice operators, d-CAIS enabled stable control of implant entry point position and insertion depth regardless of the registration method used. In contrast, angular accuracy and procedural efficiency were influenced by registration strategies and system-related characteristics. These findings suggest that selection of appropriate registration methods may play an important role in optimizing accuracy and workflow efficiency during the early learning phase of d-CAIS.

Indexed as

Clinical CompetenceDental Implantation, EndosseousSurgery, Computer-AssistedCone-Beam Computed TomographyDental ImplantsHumansIn Vitro TechniquesDental ImplantsAccuracyComputer-assisted implant surgeryDynamic navigation

Identifiers

PMID41915368
PMCPMC13038723

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.