Evidence map›Paper›PMID 41911429›Full record

ArticleAnalytical chemistry2026

Sponge-Based Flow Control in Laminate Capillary-Driven Electrochemical Microfluidic Devices for Viscous Sample Analysis.

Diele A G Araújo, Thaisa A Baldo, Thiago R L C Paixão, Charles S Henry

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Diele A G AraújoInstitute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, São Paulo, SP 05508-000, Brazil.ORCID 0000-0002-9089-8701
Thaisa A BaldoDepartment of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States.
Thiago R L C PaixãoInstitute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, São Paulo, SP 05508-000, Brazil.ORCID 0000-0003-0375-4513
Charles S HenryDepartment of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States.ORCID 0000-0002-8671-7728

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microfluidic systems are an attractive strategy for developing environmentally safer analytical methods and collecting real-time information to perform ″in loco″ analyses. Laminate capillary-driven microfluidic devices are a promising approach that can achieve fast results using low-cost devices. Despite significant advancements in capillary-driven microfluidic devices, analyzing viscous samples, particularly biological fluids, remains a challenge because the flow is highly dependent on the viscosity of the solution. Additionally, there has been a limited ability to control the flow rate. Herein, we proposed a laminate capillary-driven microfluidic device to overcome the flow issues where commercial sponges are used as passive pumps. A capillary-driven microfluidic device was coupled to electrochemical detection to provide quantitative results. After optimization, sponges provide sufficient control flow independent of the material type used to make the device. Additionally, the proposed microfluidic design enables analysis using higher viscosity solutions without compromising the electrochemical signal. The device was used to quantify paracetamol in undiluted human saliva using a generator-collector mode, with a recovery rate of nearly 100%. An important finding in this work was the possibility of analyzing viscous saliva without requiring any dilution. Additionally, the new design, which utilizes the sponge as a passive pump, opens the possibility of performing reactions (sample preparation steps) within the microfluidic channel, as the flow can be controlled by simply replacing the sponge. These results pave the way for the development of capillary-driven microfluidic devices with electrochemical detection for saliva analysis outside laboratory settings.

Indexed as

AcetaminophenElectrochemical TechniquesLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesSalivaHumansViscosityAcetaminophen

Identifiers

PMID41911429
PMCPMC13084631

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.