Evidence map›Paper›PMID 41910024›Full record

ArticleAnalytical chemistry2026

A Miniaturized Two-Electrode Detection System for Convenient and Rapid Ferricyanide-Mediated Chemical Toxicity Screening.

Krittamate Buppasirakul, Wipa Suginta, Albert Schulte

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Krittamate BuppasirakulSchool of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Wang Chan Valley, Rayong 21210, Thailand.
Wipa SugintaSchool of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Wang Chan Valley, Rayong 21210, Thailand.
Albert SchulteSchool of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Wang Chan Valley, Rayong 21210, Thailand.ORCID 0000-0002-3034-6075

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Toxicity bioassays play a crucial role in chemical risk assessment; however, conventional methods usually require specialized equipment, and limited accessibility is a significant drawback. Here, we present a user-friendly version using a simple two-electrode ferricyanide-mediated scaling of microbial respiration for rapid, convenient, and reliable toxicity assessment. The electrochemical cell is designed for continuous pulse-amperometric analysis, eliminating the need for disassembly/assembly and enabling a straightforward protocol to obtain a comprehensive evaluation of bacterial viability across a specific toxicant gradient in a single test run. Dose-response toxicity trends were directly observable, and half-maximal inhibitory concentration (IC

Indexed as

Electrochemical TechniquesFerricyanidesMiniaturizationToxicity TestsCarbarylChlorophenolsElectrodes3,5-dichlorophenolCarbarylChlorophenolsFerricyanides

Identifiers

PMID41910024
PMCPMC13084621

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.