ArticleACS omega2026
Potentiometric Bipolar Batteries for Ion Sensing. 3D Printed Comb Sensors.
Article in ACS omega, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We propose a concept leading to pronounced sensitivity increase of potentiometric analysis based on application of potentiometric bipolar batteries. The system is composed of an array of individual cells; each of them is comprising an ion-selective electrode (ISE) and a reference silver/silver chloride electrode. The cells are connected in series in the absence of additional wiring but form closed bipolar electrode systems composed of ISE and the reference electrode of the neighboring cell. Advantageously, the cell arrays are produced by a 3D printing method using biodegradable polylactide filaments. Potentiometric studies were carried out on model examples of potassium ISEs, supplemented by results obtained also for calcium-ISES to compare the role of the analyte ion charge. It was found that the recorded slope of linear dependence of the voltage on logarithm of potassium and calcium ions activity corresponds to the Nernstian value multiplied by the number of cells. The selectivity of the proposed system with potassium-ISE is high and equal to that of a single electrode. This approach was found applicable for real samples within physiological range of potassium ions concentration; moreover, due to enhanced sensitivity, a linear dependence of the voltage directly on potassium ions concentration in physiological range was obtained, with concentration resolution error smaller than 1%.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.