Evidence map›Paper›PMID 41908210›Full record

ArticleHeart rhythm O22026

First-in-human experience for cardiac arrhythmia mapping using a novel ultra-high-density globe-shaped catheter from the multicenter COSMOS study.

Ante Anic, Massimo Grimaldi, Tom De Potter, Carlo de Asmundis, Gian Battista Chierchia, Federico Quadrini, Antonio di Monaco, Toni Brešković, Moussa Mansour, Hiroshi Nakagawa and 1 more

Abstract read
In one paragraph

Article in Heart rhythm O2, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ante AnicUniversity Clinical Hospital Split, Split, Croatia.
Massimo GrimaldiOspedale Generale Regionale F. Muilli, Acquaviva delle Fonti, Italy.
Tom De PotterOnze Lieve Vrouwziekenhuis Hospital, Aalst, Belgium.
Carlo de AsmundisUniversitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Laarbeeklaan, Brussels, Belgium.
Gian Battista ChierchiaUniversitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Laarbeeklaan, Brussels, Belgium.
Federico QuadriniOspedale Generale Regionale F. Muilli, Acquaviva delle Fonti, Italy.
Antonio di MonacoOspedale Generale Regionale F. Muilli, Acquaviva delle Fonti, Italy.
Toni BreškovićUniversity Clinical Hospital Split, Split, Croatia.
Moussa MansourMassachusetts General Hospital, Boston, Massachusetts.
Hiroshi NakagawaCleveland Clinic, Cleveland, Ohio.
Alexandre AlmoradUniversitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Laarbeeklaan, Brussels, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: A novel ultra-high-resolution mapping system (Clarysense, Biosense Webster, Inc) has been developed that consists of a 100-electrode deflectable bidirectional basket-shaped high-density mapping catheter that incorporates a central TRUEref electrode and is integrated with the CARTO 3 system. Objective: This study aimed to assess the clinical safety and performance of the novel system for mapping in complex atrial and ventricular arrhythmias. Methods: This prospective, single-arm, multicenter study included patients undergoing catheter mapping and ablation of atrial and ventricular arrhythmias. Mapping was performed with the study catheter, and participants were ablated per the investigator's standard of care. The primary effectiveness endpoint was completion of preablation electroanatomic mapping without resorting to a nonstudy catheter. The primary safety endpoint was the incidence of device-related serious adverse events within 7 days. Physician feedback on catheter performance was collected using a 7-point Likert scale. Results: 40 participants (mean age 58.0 ± 15.73 years; 62.5% male; 30 with atrial arrhythmias, 10 with ventricular arrhythmias) underwent mapping with the study catheter. The primary effectiveness endpoint was achieved in all participants; ≥1 area of interest for mappable rhythms was identified in 23 of 30 participants with atrial arrhythmia. One serious adverse event of transient complete atrioventricular block was reported in a participant with persistent atrial fibrillation during preablation mapping, with full recovery. Physician feedback indicated that the device met or exceeded expectations for signal quality; most responders rated highly on bipolar signal quality in atria and noise encountered. Conclusion: In this first-in-human study, the novel mapping system improved high-density mapping in complex arrhythmias with high-quality signals and map resolution. The catheter exceeded operators' expectations in signal fidelity.

Indexed as

Atrial flutterAtrial tachycardiaElectroanatomic mappingHigh resolutionParoxysmal atrial fibrillationPersistent atrial fibrillationPremature ventricular complexVentricular tachycardia

Identifiers

PMID41908210
PMCPMC13031029

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.