Evidence map›Paper›PMID 41907261›Full record

ArticleFrontiers in medicine2026

Improved YOLOv8 with average pooling downsampling for detection and classification of intertrochanteric femoral fractures in X-ray images: a study focusing on AO/OTA classification.

Zheming Shen, Yu Wang, Yu Chen, Haowen Lu, Can Tang, Zhiheng Gao, Xuequan Zhao, Haifu Sun, Yuchen Qian, Youbin Zhang and 1 more

Abstract read
In one paragraph

Article in Frontiers in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Zheming Shen *Xiangcheng District Caohu People's Hospital, Suzhou, China.
Yu Wang *Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Yu Chen *Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Haowen Lu *Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Can TangDepartment of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Zhiheng GaoDepartment of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Xuequan ZhaoCangzhou Integrated Traditional Chinese and Western Medicine Hospital, Cangzhou, China.
Haifu SunDepartment of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Yuchen QianDepartment of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Youbin ZhangDepartment of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.
Yusen QiaoDepartment of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study aims to develop an artificial intelligence system for the accurate detection and classification of intertrochanteric femoral fractures (types A1-A3 according to the AO/OTA classification) in X-ray images, focusing on improving precision and optimizing computational efficiency. Methods: This study adopted a retrospective design, using 976 X-ray image datasets collected from hospital archives. The images were preprocessed, annotated by orthopedic specialists, and divided into training and test sets. The model was improved by replacing the traditional convolutional downsampling modules in YOLOv8 with Average Pooling Downsampling (ADown) modules to enhance feature extraction for small fracture targets. Model training incorporated data augmentation techniques and was evaluated using metrics such as precision, recall, and mean Average Precision (mAP). Results: The proposed YOLOv8-ADown model achieved an overall mAP50 of 81.7%, higher than the 80.5% of the original YOLOv8. The detection precision for A1, A2, and A3 type fractures increased by 7.3, 3.5, and 7.8%, respectively. Furthermore, the number of model parameters was reduced by 12.3%, and computational complexity (FLOPs) was decreased by 9.8%, demonstrating potential for deployment on edge devices. Conclusion: The YOLOv8-ADown model provides an efficient solution for fracture detection and is expected to assist in clinical diagnosis. Future work should address data collection challenges and conduct multi-center validation.

Indexed as

artificial intelligencehip fractureintertrochanteric femoral fracturemedical imagingobject detectionYOLOv8

Identifiers

PMID41907261
PMCPMC13020046

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.