Evidence map›Paper›PMID 41906090›Full record

ArticleBMC pregnancy and childbirth2026

The role of sonographic estimated fetal weight compared to clinical assessment: superior accuracy only in extreme fetal weight cases.

Lior Heresco, Chaya Ben Yehuda, Romi Cohen Rappaport, Hadar Gluska, Tal Biron-Shental, Omer Weitzner

Abstract readComparative Study
In one paragraph

Article in BMC pregnancy and childbirth, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Lior HerescoDepartment of Obstetrics and Gynecology, Meir Medical Center, 59 Tchernichovsky St, Kfar Saba, Israel. lior160@gmail.com.
Chaya Ben YehudaClalit Health Services, Tel Aviv, Israel.
Romi Cohen RappaportGray Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Hadar GluskaDepartment of Obstetrics and Gynecology, Meir Medical Center, 59 Tchernichovsky St, Kfar Saba, Israel.
Tal Biron-ShentalDepartment of Obstetrics and Gynecology, Meir Medical Center, 59 Tchernichovsky St, Kfar Saba, Israel.
Omer WeitznerDepartment of Obstetrics and Gynecology, Meir Medical Center, 59 Tchernichovsky St, Kfar Saba, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEstimated fetal weight (EFW) is of key importance in antenatal care, as inaccuracies can contribute to adverse outcomes and unnecessary interventions. However, both clinical and sonographic methods for EFW have demonstrated limited accuracy, and different factors were found to be associated with increased error range. This study aimed to compare the accuracy of sonographic and clinical EFW methods and identify factors influencing estimation errors.

methodsThis retrospective analysis included singleton pregnancies delivering at ≥ 37 weeks of gestational age between 2014 and 2023. Participants with recorded clinical and sonographic EFW within 14 days of delivery were included. Exclusion criteria included multiple gestations, absence of either clinical or sonographic EFW, and incomplete data. EFW accuracy was evaluated against actual neonatal birthweight using overall absolute error and absolute percent error, using paired t-test. Differences in error categories (> 10% and > 20%), specificity, sensitivity, positive predictive value (PPV) and negative predictive value (NPV) were evaluated using McNemar test. Subgroup analyses included normal weight ( (BMI 18.5–24.9), obese patients (BMI ≥ 30), tall women (height > 172 cm), nulliparous and multiparous women, and neonates with birth weights ≥ 4500 g, 4000–4499 g, and ≤ 2500 g. Logistic regression identified factors associated with > 10% error in each method.

resultsOut of 61,531 term deliveries in the study period,14,400 women were included in the study. Sonographic EFW demonstrated significantly higher accuracy among birthweights extremes of ≤ 2500 g and ≥ 4500 g with lower mean absolute percent error in these groups (11.3% vs. 15.0% and 10.6% vs. 12.3%, respectively). Clinical estimation showed a higher negative predictive value for ruling out extreme birthweight (54.9% vs. 44.1%), supporting its usefulness as a first-line screening tool in routine obstetric care. While statistically significant differences were observed in favor of sonographic EFW across other subgroups and the entire study population, no differences of clear clinical relevance were found, as absolute differences were minimal. Low birth weight, macrosomia ≥ 4500 g and nulliparity were associated with a high estimation error in both sonographic and clinical EFW, with a greater extent observed in clinical EFW.

conclusionsSonographic EFW exhibits superior accuracy in cases of extreme birth weights (≤ 2500 g and ≥ 4500 g). Among other populations, differences between sonographic and clinical EFW were minimal and of limited clinical relevance. This knowledge should be incorporated into daily practice and decision-making processes to ensure optimal patient care.

Indexed as

Fetal WeightUltrasonography, PrenatalAdultBirth WeightFemaleFetal MacrosomiaGestational AgeHumansInfant, NewbornPredictive Value of TestsPregnancyRetrospective StudiesSensitivity and SpecificityClinical examinationFetal weight estimationLeopold's maneuversUltrasound

Identifiers

PMID41906090
PMCPMC13154497

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.