ArticleMedical physics2026
Real-time energy measurement of clinical carbon ion beams using a cross-correlation time-of-flight method with parallel-plate chambers.
Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors.
Funding
Abstract
backgroundIn carbon-ion radiotherapy (CIRT), the beam energy determines both the particle range and the overall dosimetric quality. Range-verification QA devices such as Zebra and Giraffe, which are based on multilayer ionization chambers (MLICs), can verify the range but only under dedicated QA conditions, leaving any energy deviations introduced by nozzle components undetected in real time. In particular, nozzle structures such as ridge filters can broaden or modulate the energy spectrum, causing the effective energy delivered to the patient to differ from the nominal accelerator setting. These limitations highlight the need for a real-time method capable of verifying the beam energy under actual clinical operating conditions. PURPOSE: We proposed a TOF-based beam-energy measurement concept that leverages a cross-correlation analysis of full detector waveforms. Compact and radiation-hard parallel-plate chambers (PPCs) were developed and evaluated, in contrast to prior TOF systems based on semiconductor detectors.
methodsPPCs (2.5 cm diameter active area, 0.4 mm gas gap) were operated in CO
resultsThe PPCs operated stably for all beam conditions. Under pencil-beam delivery and normalized to 1 s acquisitions, the timing precision of the mean TOF (standard error) remained within 1 ps for both detector separations, scaling with
conclusionsWe demonstrated that compact CO