ArticleBMC musculoskeletal disorders2026
Does the distal screw location in the Biplane double-supported screw fixation technique affect the risk of subtrochanteric fractures after femoral neck fixation? A finite element analysis.
Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Biomechanical and clinical evaluation of the posterosuperior screw in-out-in in the inverted triangular cannulated screws fixation of femoral neck fractures.Frontiers in bioengineering and biotechnology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundResearch indicates that in the traditional method of cannulated screw fixation for femoral neck fractures, placing the distal screw beyond the lesser trochanter increases the risk of subtrochanteric fractures. In the Biplane double-supported screw fixation technique (BDSF), the lowest screw needs to be inserted at a high inclination angle, making its entry point further from the lesser trochanter. This could increase the risk of iatrogenic subtrochanteric fractures and compromise the stability of the fracture fixation structure. However, there is currently a lack of research on this issue.
methodsUsing BDSF technology to treat Pauwels III femoral neck fractures, we established finite element analysis models with three different distal screw insertion positions (models a, b, c). We determined a range on the lateral cortex midline of the femoral shaft that meets all the requirements for distal screw insertion using BDSF technology. The distal screws were inserted at three positions within this range: upper, middle, and lower, marked as A, B, and C, respectively. Model a: fracture fixation model with insertion point at (A) Model b: fracture fixation model with insertion point at (B) Model c: fracture fixation model with insertion point at (C) Under the same load conditions, finite element analysis was performed on the displacement of the internal fixation and femur, the stress distribution, and the stress distribution in the subtrochanteric region for the three models.
resultsAmong the three models we studied, there was no statistically significant difference in the stress magnitude in the subtrochanteric region.Model b had the lowest peak stress values for both the femur and the internal fixation, with displacement values of the femur and internal fixation being close to the minimum. Overall, implanting the distal screw in the middle of the reasonable range of screw placement can provide better stability.
conclusionsFrom the perspectives of the maximum displacement of the femur and internal fixation, the maximum stress, and the stress distribution in the subtrochanteric region, implanting the distal screw from the middle position can provide better stability for the fracture ends without increasing the risk of subtrochanteric fractures.