Evidence map›Paper›PMID 41902990›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Comparative evaluation of additively manufactured PLA models as cost-effective, non-inferior alternatives to composite bones for pull-out testing.

Utku Demirtaş, Osman İyibilgin, Levent Bayam, Erdinç Genç

Abstract readComparative Study
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Utku DemirtaşDepartment of Orthopaedics and Traumatology, Sultan 1. Murat State Hospital, Edirne, Turkey. opdrutkudemirtas@gmail.com.
Osman İyibilginMechanical Engineering Department, Sakarya University, Sakarya, Turkey. ibilgin@sakarya.edu.tr.
Levent BayamDepartment of Orthopaedics and Traumatology, Istanbul Medipol University, Istanbul, Turkey.
Erdinç GençDepartment of Orthopaedics and Traumatology, Istanbul Medipol University, Istanbul, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe purpose of this study was to perform biomechanical pull-out comparisons between composite bone blocks and additively manufactured bone models using locked plate and screw systems. The hypothesis posited that the mean pull-out force of the 3D-printed models would demonstrate non-inferior pull-out strength compared to standard composite bones within a clinically acceptable 15% margin. A standardized pull-out mechanism was developed to evaluate its biomechanical reliability and its potential as a customizable alternative. MATERIALS AND

methodsThe study compared three groups: standard composite (Sawbones) blocks and two types of additively manufactured polylactic acid (PLA) blocks (grid and gyroid infill pattern), each measuring the same dimensions with 30% infill and mimicking a Sawbones block with 2 mm cortical thickness. A 6-hole LC-DCP titanium plate was fixed onto bone block models with dimensions of 29 × 170 × 42 mm using four screws, each measuring 36 mm in length, which were inserted perpendicularly and tightened to the same torque levels. Steel cables placed under the plate were connected to a mechanical testing setup, and pull-out tests were conducted to evaluate fixation strength. Seven replicate specimens were fabricated to ensure repeatability and reliability of the results.

resultsMean pull-out forces were 1784.4 ± 79.9 N for Sawbones, 1698.5 ± 134.3 N for Grid PLA (n = 7), and 1908.7 ± 335.2 N for Gyroid PLA (n = 7). Statistical analysis using a one-sample t-test showed that both 3D-printed models were non-inferior to the standard Sawbones model within a clinical acceptance margin of 15% (p < 0.05).

conclusionsAdditively manufactured models exhibit mechanical pull-out performance that is statistically non-inferior to traditional composite bone block models. These findings confirm that 3D-printed PLA-based grid and gyroid structures serve as reliable, cost-effective alternatives for orthopaedic mechanical research without compromising mechanical integrity.

Indexed as

Materials TestingModels, AnatomicPolyestersPrinting, Three-DimensionalBiomechanical PhenomenaBone PlatesBone ScrewsCost-Benefit AnalysisHumansMechanical TestsReproducibility of ResultsPolyesterspoly(lactide)3D-printed bone modelAdditive manufacturingComposite bone modelMechanical testingPolylactic acid (PLA)Pull-out strength

Identifiers

PMID41902990
PMCPMC13032990

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.