ArticleSensors (Basel, Switzerland)2026
Optical Caliper for Contactless Measurement of Plant Stem Diameter.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Precision greenhouse agriculture enhances plant health and crop yields by continuously monitoring key plant parameters. Stem diameter is such a parameter and is monitored to support decisions on plant care. However, traditional contact-based methods induce thigmomorphogenic effects that impact plant growth. Here, we introduce the Optical Caliper (OC), a novel contactless device for precise, non-invasive stem diameter measurement. The OC operates by projecting a collimated light beam to cast a shadow of the stem onto a high-resolution image sensor. The shadow size is a measure for the stem diameter. Controlled laboratory tests show the OC offers an accuracy comparable to that of a Digital Caliper (DC). Field trials on irregular tomato and cucumber stems demonstrate a repeatability of 0.1-0.2 mm. The OC's non-invasive design and high repeatability exceed the performance of a DC, making it particularly suited for accurately monitoring soft, variable plant structures. Bringing the advantage of avoiding thigmomophogenic effects and thus optimizing crop yield, the OC is a promising tool for high-throughput plant phenotyping and precision agriculture applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.