A Real-Time Mechanical Information Acquisition System and Finite Element Prediction Method for Limb Lengthening: A Pilot In Vivo Study.

Hao Yang, Tairan Peng, Yuyang Han, Ming Lu, Yunzhi Chen, Zheng Yang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hao YangPediatric Orthopaedics Department, National Center for Orthopaedics, Beijing Jishuitan Hospital, Capital Medical University, Beijing 100096, China.
Tairan PengDepartment of Mechanical Engineering, Tsinghua University, Beijing 100084, China.
Yuyang HanPediatric Orthopaedics Department, National Center for Orthopaedics, Beijing Jishuitan Hospital, Capital Medical University, Beijing 100096, China.
Ming LuPediatric Orthopaedics Department, National Center for Orthopaedics, Beijing Jishuitan Hospital, Capital Medical University, Beijing 100096, China.
Yunzhi ChenDepartment of Mechanical Engineering, Tsinghua University, Beijing 100084, China.
Zheng YangPediatric Orthopaedics Department, National Center for Orthopaedics, Beijing Jishuitan Hospital, Capital Medical University, Beijing 100096, China.

Funding

Beijing Hospitals Authority Youth Programme QML20230403Beijing Municipal Health Commission BJRITO-RDP
6 · The paper itself

Abstract

In the field of orthopedic surgery, particularly distraction osteogenesis (DO), the mechanical environment plays a decisive role in the quality of bone regeneration and the safety of the soft tissue envelope. The continuous monitoring and accurate prediction of distraction resisting forces (DRF) are critical for preventing soft tissue complications such as nerve ischemia, joint contractures, and mechanical failure of the lengthening device. However, current clinical practice relies heavily on subjective assessment or passive monitoring tools that lack predictive capabilities. To address this gap, this study proposes a comprehensive solution combining a custom mechanical acquisition system with a high-fidelity finite element (FE) prediction method. The system design features a novel "double-ring" sensor interface specifically engineered to decouple axial distraction forces from parasitic bending moments generated by asymmetric muscle tension. Furthermore, a patient-specific FE model utilizing the Ogden hyperelastic constitutive law was derived, explicitly based on the patient's muscle volume from preoperative CT imaging, to predict the non-linear force evolution. The feasibility and accuracy of the system were validated in a pilot in vivo study using a single ovine model (N=1). To isolate the soft tissue resistance from callus formation, distraction was performed immediately postoperatively up to a total length of 4 cm. Experimental results demonstrated the system's high linearity (R2>0.999) and its ability to capture the characteristic viscoelastic relaxation of living tissues. The FE model successfully predicted the peak distraction forces, showing improved agreement with experimental data at larger distraction magnitudes. By integrating mechanical sensing with predictive modeling, this framework lays the foundation for future closed-loop, patient-specific control in distraction osteogenesis.

Indexed as

Finite Element AnalysisOsteogenesis, DistractionAnimalsBiomechanical PhenomenaHumansPilot ProjectsSheepdigital twindistraction forcefinite element predictionin vivo validationlimb lengtheningmechanical acquisition systemsoft tissue mechanics

Identifiers

PMID41902119
PMCPMC13029876

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.