ArticleSensors (Basel, Switzerland)2026
Uncertainty Effects on Smart Grid Services for Low-Voltage Distribution Networks.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Telemetry-Robust Safe Zero-Shot Graph Multi-Agent Reinforcement Learning for Active Voltage Control Across Distribution Feeders.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
This study investigates the impact of monitoring infrastructure characteristics (specifically sensor penetration and measurement accuracy) on the effectiveness of voltage regulation and congestion management within distribution networks. As distribution system operators transition toward active management, the integration of Distributed renewable Generation (DG) and demand response introduces significant physical and cyber-physical uncertainties. To address these challenges, a smart grid service framework has been employed to optimize flexibility resources from aggregated users and DG inverters through a genetic algorithm. The framework was tested on the IEEE European Low Voltage Test Feeder across various scenarios defined by distributed monitoring systems' penetration and their measurement accuracy. Results show that sensor penetration has a dominant impact: increasing monitoring coverage from 0% to 100% raises the percentage of cases with fewer than one residual congestion from 46.2% to 91.9% (sensors with an accuracy class of 2%), reaching 97.9% with an accuracy class of 0.5%, while voltage violations are eliminated under full monitoring. These findings suggest that widespread sensor deployment, with a suitable measurement accuracy, is a fundamental prerequisite for reliable and efficient smart grid operation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.