ArticleSensors (Basel, Switzerland)2026
An Integrated Pixel-Level Reflectance Adjustment (IPRA) for Harmonizing GF-1/6 WFV and Sentinel-2 MSI Data.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
This study proposes an integrated pixel-level reflectance adjustment (IPRA) method using Sentinel-2 MSI as the reference to address radiometric discrepancies in GF-1/6 WFV imagery, particularly caused by sensor decay and geometric distortions. The proposed IPRA method leverages time-series data and a spatial heterogeneity detection mechanism to effectively mitigate geometric distortions. Furthermore, it incorporates a weighted linear regression (WLR) model to weight pixels based on their temporal decay characteristics. The results demonstrate that IPRA outperforms existing methods (i.e., IRMAD, HM, and TRA) in radiometric consistency, yielding smaller radiometric discrepancies relative to Sentinel-2 MSI. Specifically, NAE decreased by 42.9% (from 0.319 to 0.182), RMSE decreased by 37.3% (from 0.051 to 0.032), PSNR improved from 25.906 dB to 30.195 dB, and the SC value approached the ideal value of 1 (from 1.540 to 1.001). In conclusion, the IPRA method provides a robust solution for normalizing GF-1/6 WFV imagery and thus facilitates its cross-sensor applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.