ArticleMicromachines2026
Real-Time External Control Combined with Image Post-Processing for Mitigating SEM Vibration Distortion.
Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Scanning electron microscopes (SEMs) are crucial for material characterization. They are highly susceptible to vibration from environmental sources, internal components, and other external factors, which can impair measurement accuracy. Traditional solutions are limited in addressing multi-source vibrations: passive isolation struggles with internal vibrations, while image post-processing cannot fundamentally correct large-amplitude deviations in the electron beam. Therefore, this study proposes a hybrid framework that combines real-time active hardware suppression with post-processing to mitigate vibration-induced distortion in SEM images. Using a self-developed external controller and software, the framework extracts periodic vibration features via FFT, quantifies scan line horizontal offset, and implements real-time inverse offset during imaging to suppress dominant-frequency vibration at the source. An adaptive median filtering algorithm is integrated with a Laplacian edge enhancement algorithm to address residual edge burrs, thereby balancing distortion suppression and detail preservation. Experiments at 100 kx magnifications demonstrate notable correction effects: the peak-to-peak value, edge transition width (ETW), and no-reference image quality (NIQE) score are reduced by 39.4%, 91.7%, and 58.9%, respectively. Consistent correction trends are observed at 50 kx, with periodic vibration distortion essentially eliminated across both magnifications. Furthermore, distortion can be regulated through the phase interaction between dwell time and vibration period, making the strategy universally applicable and easy to implement. Without the need for vibration source localization, the framework is compatible with various types of vibration interference. It provides a solution for mitigating vibration impacts in high-magnification, precise characterization of SEMs and offers a reference for anti-vibration optimization of other microscopic techniques, such as transmission electron microscopy (TEM) and atomic force microscopy (AFM).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.