Evidence map›Paper›PMID 41899817›Full record

ArticleBioengineering (Basel, Switzerland)2026

Efficient Interleaved Multi-Band Outer Volume Suppression for Highly Accelerated Simultaneous Multi-Slice Imaging of the Heart.

Ayda Arami, Omer Burak Demirel, Toygan Kilic, Steen Moeller, Yidong Zhao, Yi Zhang, Qian Tao, Hildo J Lamb, Mehmet Akçakaya, Sebastian Weingärtner

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ayda AramiDepartment of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands.ORCID 0009-0001-4111-3357
Omer Burak DemirelPhilips North America, Rochester, MN 55902, USA.ORCID 0000-0003-4726-0590
Toygan KilicDepartment of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA.ORCID 0000-0001-7969-5738
Steen MoellerCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA.ORCID 0000-0003-1698-7260
Yidong ZhaoDepartment of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands.ORCID 0000-0003-3953-6921
Yi ZhangDepartment of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands.ORCID 0000-0003-0523-3877
Qian TaoDepartment of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands.ORCID 0000-0001-7480-0703
Hildo J LambDepartment of Radiology, Leiden University Medical Center, 2333 ZG Leiden, The Netherlands.ORCID 0000-0002-6969-2418
Mehmet AkçakayaDepartment of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA.ORCID 0000-0001-6400-7736
Sebastian WeingärtnerDepartment of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands.ORCID 0000-0002-0739-6306

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger, KAMIL UGURBIL · 2019 to 2026
$11.7M
Rapid Comprehensive Cardiac MRI Exam for Diagnosis of Coronary Artery DiseaseR01HL153146 · NHLBI · UNIVERSITY OF MINNESOTA · PI AKCAKAYA, MEHMET · 2020 to 2024
$2.5M
4TU Precision Medicine program supported by High Tech for a Sustainable Future NAEuropean Research Council 101078711LUMC-TU Delft Delft Health Initiative NANederlandse Organisatievoor Wetenschappelijk Onderzoek STU.019.024NHLBI NIH HHS R01HL153146NIBIB NIH HHS P41EB027061the Nederlandse Hartstichting 03-004-2022-0079
6 · The paper itself

Abstract

In this work, we aimed to develop and evaluate multi-band outer volume suppression pulses for increased acceleration rates in simultaneous multi-slice accelerated cardiac MRI. MB-OVS pulses were constructed from a multi-band combination of two slab-selective saturation pulses and tested for various pulse shapes using Bloch simulation and phantom experiment. The MB-OVS pulses were interleaved between imaging pulses to ensure homogeneous suppression throughout the cardiac cycle/imaging window in vivo. Simultaneous multi-slice (SMS) CINE and first-pass myocardial perfusion scans with and without the proposed MB-OVS pulses were compared in terms of residual artifacts at high acceleration rates. Among the tested pulses, both Bloch simulation and phantom experiments showed that amplitude-optimized sinc pulses provided the best trade-off in suppression efficiency, the required B1+, SAR, and slab profile. CINE imaging with 5-fold SMS-OVS acceleration significantly outperformed imaging without MB-OVS, maintaining leakage-free image quality, even when adding 2-fold in-plane acceleration. SMS-OVS also enabled perfusion imaging in 9 slices with 1.7 × 1.7 mm

Indexed as

cardiac MRIouter volume suppressionsimultaneous multi-slice imaging

Identifiers

PMID41899817
PMCPMC13024669

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.