Test-Retest Reliability and Validity of a Sums-of-Gaussians-Based Markerless Motion Capture System for Human Lower-Limb Gait Kinematics.
Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
BACKGROUND AND
aimTraditional marker-based optical motion capture systems are costly, time-consuming to operate, and constrained by laboratory environments, limiting their broader adoption in clinical practice and naturalistic settings. Markerless motion capture based on a sums-of-Gaussians (SoG) body model is a potential alternative; however, its metrological properties for kinematic assessment during walking and slow running remain insufficiently validated. Using a conventional marker-based Vicon system as the reference, this study evaluated the reliability and concurrent validity of an SoG-based markerless system (MocapGS) for bilateral lower-limb joint range of motion (ROM) during gait.
methodsThirty-six healthy adults completed self-selected-pace speed walking and slow running tasks while both systems synchronously acquired bilateral lower-limb kinematics. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), SEM percentage (SEM%), minimal detectable change (MDC), MDC percentage (MDC%), and root mean square error (RMSE) were used to assess reliability. Concurrent validity was evaluated using the Pearson correlation coefficient, paired-sample t-tests, and the concordance correlation coefficient (CCC) to compare the ROM.
resultsVicon showed moderate-to-high reliability for ROM in most joints across both tasks. By contrast, the MocapGS achieved acceptable ICC values mainly for the sagittal-plane ROM at the hip and knee. The CCC analysis showed no significant agreement between the two systems. Bland-Altman plots showed systematic biases with spatially heterogeneous random errors. During walking, MocapGS systematically overestimated ROM relative to Vicon at several joint axes; the widest limits of agreement (LOA) occurred at the left knee X-axis and right hip Z-axis. During running, overestimation was consistent across all bilateral joints at the X-axis and the right hip at the Y-axis, while the widest LOA were found at the bilateral hip X-axes. These specific discrepancies highlighted the joint-axis combinations with the greatest measurement variance. In walking, the test-retest reliability of the knee flexion-extension ROM measured by the MocapGS approached that of Vicon; however, the SEM% and MDC% were generally larger for MocapGS than for Vicon. The RMSE exceeded 5 degrees for ROM in most joint planes, especially in the frontal and transverse planes and at distal joints; errors increased further during slow running.
conclusionsMocapGS may be used for coarse monitoring of large-magnitude changes in sagittal-plane kinematics during gait; however, it is currently unlikely to replace Vicon for clinical decision-making or detecting subtle gait changes, and its outputs should be interpreted with caution, particularly for ankle kinematics and non-sagittal-plane motion.