Evidence map›Paper›PMID 41892928›Full record

ArticleJournal of imaging2026

Parameter Selection in Coupled Dynamical Systems for Tomographic Image Reconstruction.

Ryosuke Kasai, Omar M Abou Al-Ola, Tetsuya Yoshinaga

Abstract read
In one paragraph

Article in Journal of imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ryosuke KasaiInstitute of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima 770-8509, Japan.ORCID 0000-0002-4699-1642
Omar M Abou Al-OlaFaculty of Science, Tanta University, El-Giesh St., Tanta 31527, Egypt.ORCID 0000-0002-7883-676X
Tetsuya YoshinagaInstitute of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima 770-8509, Japan.ORCID 0000-0003-4994-0522

Funding

Japan Society for the Promotion of Science 24K07507
6 · The paper itself

Abstract

This study investigates the performance of image-reconstruction methods derived from coupled dynamical systems for solving linear inverse problems, focusing on how appropriate parameter selection enhances noise-suppression capability in tomographic image reconstruction. Our previous work has established the stability of linear and nonlinear variants of such systems on the basis of Lyapunov's theorem. However, the influence of parameter choice on reconstruction quality has not been fully clarified. To address this issue, we introduce a parameter adjustment strategy based on an optimization principle. Two complementary optimization strategies are considered. The first employs ground-truth images to determine optimal parameter values that serve as a numerical benchmark for evaluating reconstruction performance. The second relies solely on measured projection data, enabling practical application without prior knowledge of the true image. Numerical experiments using phantoms with relatively high noise levels demonstrate that appropriate parameter selection markedly improves reconstruction accuracy and robustness. These results clarify how properly tuned reconstruction methods derived from coupled dynamical systems can effectively exploit their inherent dynamics to achieve noise suppression in tomographic inverse problems.

Indexed as

computed tomographycoupled dynamical systemiterative reconstructionoptimizationparameter selection

Identifiers

PMID41892928
PMCPMC13027923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.