Influence of Off-Centre Positioning, Scan Direction, and Localiser Projection Angle on Organ-Specific Radiation Doses in Low-Dose Chest CT: A Simulation Study Across Four Scanner Models.

Louise D'hondt, Claudia Haentjens, Pieter-Jan Kellens, Annemiek Snoeckx, Klaus Bacher

Abstract read
In one paragraph

Article in Journal of imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Louise D'hondtDepartment of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, 9000 Ghent, Belgium.
Claudia HaentjensDepartment of Physics and Astronomy, Faculty of Sciences, Ghent University, 9000 Ghent, Belgium.
Pieter-Jan KellensDepartment of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, 9000 Ghent, Belgium.
Annemiek SnoeckxFaculty of Medicine, University of Antwerp, 2610 Wilrijk, Belgium.ORCID 0000-0003-2101-2783
Klaus BacherDepartment of Human Structure and Repair, Faculty of Medicine and Health Sciences, Ghent University, 9000 Ghent, Belgium.ORCID 0000-0001-6420-6006

Funding

Research Foundation - Flanders G0B1922N
6 · The paper itself

Abstract

With the considerable number of low-dose CT examinations performed in lung cancer screening, variations in participant positioning, scan direction, or localiser angle are likely to occur in practice. These variations are known to affect automatic tube current modulation (ATCM) operation, yet organ-specific dose implications across CT models remain unknown. Therefore, this simulation study systematically characterised the effect of the aforementioned variations. Using the Alderson RANDO phantom, ATCM profiles were established on CT scanners from four major vendors (GE, Siemens, Canon, Philips) after introducing vertical and lateral mispositioning, craniocaudal and caudocranial scan directions, and varying localiser projection angles. Additionally, off-centre positioning and scan direction changes preceded by either a single posteroanterior (PA) or dual (PA+lateral) localiser were evaluated. Doses to the lungs, heart, thyroid, liver, and breasts were calculated from Monte Carlo simulations of each setup for 32 patient-specific voxel models. The results demonstrate statistically significant and scanner-dependent dose variations. PA localisers generally produced the highest organ doses. However, on the Philips system, organ dose increases of at least 50% were observed after the lateral projection angle. GE and Siemens scanners showed pronounced dose increases following downward mispositioning with a single PA localiser (18-50% and 5-25%, respectively), an effect largely mitigated by adding a lateral localiser. Canon and Philips scanners exhibited generally stable ATCM behaviour after vertical off-centring, although Canon showed notable dose increases upon lateral mispositioning, with dose increases up to 37.5% and 34% after a single PA or dual localiser, respectively. Variations in scan direction displayed highly model- and organ-dependent effects. Dose deviations were largely mitigated after dual localisers for the GE, Canon, and Philips scanner types. Here, organ dose differences were within an absolute range of 10%, indicating that a change in scan direction preceded by a dual localiser can reduce extreme dose deviations. Remarkably, no significant difference was observed solely for the Siemens scanner when combined with a dual localiser, as lung, heart, breast, and liver doses remained significantly (between 20 and 35%) lower when scanning craniocaudally, whereas the thyroid dose in this setup remained considerably higher (up to 20% mean increase). Ultimately, findings indicate that seemingly minor protocol deviations can lead to significant underestimation of anticipated organ-specific doses associated with lung cancer screening. Scanner-specific optimisation, supported by medical physics expertise, is therefore essential.

Indexed as

automatic tube current modulationlocaliser radiographlow-dose computed tomographylung cancer screeningMonte Carlo simulationsoff-centre positioningradiation dosimetryscan direction

Identifiers

PMID41892925
PMCPMC13028044

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.