Evidence map›Paper›PMID 41892901›Full record

ArticleJournal of imaging2026

Design and Development of an Automated Pipeline for Medical Hyperspectral Image Acquisition, Processing, and Fusion.

Felix Wühler, Tim Markus Häußermann, Alessa Rache, Björn van Marwick, Carmen Wängler, Julian Reichwald, Matthias Rädle

Abstract read
In one paragraph

Article in Journal of imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Felix WühlerCeMOS-Research and Transfer Center, Technical University of Applied Sciences Mannheim, Paul-Wittsack-Straße 10, 68163 Mannheim, Germany.ORCID 0000-0002-4821-8549
Tim Markus HäußermannCeMOS-Research and Transfer Center, Technical University of Applied Sciences Mannheim, Paul-Wittsack-Straße 10, 68163 Mannheim, Germany.ORCID 0000-0002-4020-4089
Alessa RacheCeMOS-Research and Transfer Center, Technical University of Applied Sciences Mannheim, Paul-Wittsack-Straße 10, 68163 Mannheim, Germany.ORCID 0000-0001-7598-8672
Björn van MarwickCeMOS-Research and Transfer Center, Technical University of Applied Sciences Mannheim, Paul-Wittsack-Straße 10, 68163 Mannheim, Germany.ORCID 0009-0005-2457-8805
Carmen WänglerBiomedical Chemistry, Clinic of Radiology and Nuclear Medicine, Medical Faculty, Mannheim of Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.ORCID 0000-0003-1161-8669
Julian ReichwaldCeMOS-Research and Transfer Center, Technical University of Applied Sciences Mannheim, Paul-Wittsack-Straße 10, 68163 Mannheim, Germany.ORCID 0000-0002-4809-5710
Matthias RädleCeMOS-Research and Transfer Center, Technical University of Applied Sciences Mannheim, Paul-Wittsack-Straße 10, 68163 Mannheim, Germany.ORCID 0000-0002-3382-7608

Funding

Bundesministerium für Forschung, Technologie und Raumfahrt 13FH017KI2
6 · The paper itself

Abstract

Automated and comprehensive processing of hyperspectral image data is increasingly important in academic research and medical technology. This study presents an automated processing pipeline that integrates hyperspectral image acquisition, analysis, multimodal fusion, and centralized data management to improve the interpretability of spectral information for biological tissue analysis. The pipeline supports modular hyperspectral data processing, fusion of complementary wavelength ranges, and scalable data storage, and was implemented in Python 3.13.3. The pipeline was evaluated using hyperspectral imaging data acquired from a coronal mouse brain section. Clustering-based analysis and spectral correlation metrics were applied to assess the impact of multimodal data fusion on spectral representation. Clustering of individual modalities yielded silhouette coefficients of 0.5879 for near-infrared data, 0.6020 for mid-infrared data, and 0.6715 for RGB data. Multimodal fusion reduced the silhouette coefficient to 0.5420 and enabled the identification of anatomical structures that were not distinguishable in any single modality. High spectral correlation coefficients exceeding 0.98 confirmed that spectral fidelity was preserved during fusion. These results demonstrate that automated multimodal hyperspectral data fusion can enhance the interpretability of biological tissue despite reduced clustering compactness. The proposed pipeline provides a structured framework for preclinical hyperspectral imaging workflows and supports exploratory biological analysis in medical imaging contexts.

Indexed as

automated image processinghyperspectral imagingmedical image analysismultimodal data fusionunsupervised clustering

Identifiers

PMID41892901
PMCPMC13027844

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.