ArticleCraniomaxillofacial trauma & reconstruction2026
Surgical Performance of 3D-Printed Polyetheretherketone (PEEK) Patient-Specific Implants and Titanium Mesh in Clinically Matched Orbital Reconstruction: A Cadaveric Study.
Article in Craniomaxillofacial trauma & reconstruction, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants.3D printing in medicine · 2026Article
- Clinical implementation of an EU MDR-compliant point-of-care manufacturing framework for patient-specific 3D-printed PEEK implants in craniomaxillofacial reconstruction.3D printing in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Orbital reconstruction following trauma remains challenging due to complex three-dimensional (3D) anatomy and limited surgical access. While pre-fabricated titanium mesh is standard, it requires extensive intraoperative manipulation and produces imaging artifacts. The 3D-printed polyetheretherketone (PEEK) patient-specific implants (PSIs) offer potential advantages; however, limited data exists for the acceptance of PEEK PSIs by surgeons compared to other established techniques. Fourteen surgeons performed simulated orbital reconstructions on nine cadaveric heads comparing titanium mesh and the 3D-printed PEEK PSIs. Titanium mesh was used for Class II orbital floor fractures, while the 3D-printed PEEK PSIs (native and radiopaque formulations) were used for Class IV defects. Surgeons were blinded to the PEEK formulation type. Outcomes included operative efficiency, handling characteristics, fit quality, and mechanical stability using validated 5-point Likert scales and objective timing. The 3D-printed PEEK PSIs demonstrated faster procedure times (9.5 ± 5.3 vs. 11.2 ± 5.1 min) and superior fit quality (2.00 ± 1.04 vs. 2.18 ± 0.60) and mechanical stability (1.67 ± 0.49 vs. 1.91 ± 0.54), with 100% rated stable versus 91% for the titanium mesh. Surgeons could not distinguish between the native and radiopaque PEEK formulations. Most surgeons (64.3%) preferred situation-dependent material selection. The 3D-printed PEEK PSIs demonstrated advantages in handling, fit quality, and mechanical stability for complex defects, while the titanium mesh showed a lower learning curve for simple reconstructions. Radiopaque enhancement expands PEEK's clinical utility without compromising handling.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.