Evidence map›Paper›PMID 41892099›Full record

ArticleBiomimetics (Basel, Switzerland)2026

Biomimetic Response of Zr-2.5Nb Alloy to Artificial Saliva with Variable pH: Corrosion Behavior and Surface Adaptation.

Viorica Ghisman, Nicoleta Bogatu, Elena Emanuela Herbei, Alina Crina Muresan, Daniela Laura Buruiana

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Viorica GhismanInterdisciplinary Research Centre in the Field of Eco-Nano Technology and Advance Materials CC-ITI, Faculty of Engineering, "Dunarea de Jos" University of Galati, 47 Domneasca, 800008 Galati, Romania.ORCID 0000-0002-3650-1021
Nicoleta BogatuInterdisciplinary Research Centre in the Field of Eco-Nano Technology and Advance Materials CC-ITI, Faculty of Engineering, "Dunarea de Jos" University of Galati, 47 Domneasca, 800008 Galati, Romania.ORCID 0000-0002-3278-3412
Elena Emanuela HerbeiInterdisciplinary Research Centre in the Field of Eco-Nano Technology and Advance Materials CC-ITI, Faculty of Engineering, "Dunarea de Jos" University of Galati, 47 Domneasca, 800008 Galati, Romania.
Alina Crina MuresanInterdisciplinary Research Centre in the Field of Eco-Nano Technology and Advance Materials CC-ITI, Faculty of Engineering, "Dunarea de Jos" University of Galati, 47 Domneasca, 800008 Galati, Romania.ORCID 0000-0002-8635-6678
Daniela Laura BuruianaInterdisciplinary Research Centre in the Field of Eco-Nano Technology and Advance Materials CC-ITI, Faculty of Engineering, "Dunarea de Jos" University of Galati, 47 Domneasca, 800008 Galati, Romania.ORCID 0000-0001-7787-8776

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The long-term performance of metallic biomaterials in the oral environment is strongly influenced by their interaction with saliva and its variable chemical conditions. In this study, the biomimetic behavior of a Zr-2.5Nb alloy was investigated during immersion in artificial saliva with acidic, neutral, and alkaline pH for a period of 28 days, aiming to simulate diverse physiological and pathological oral conditions. The evolution of saliva pH was continuously monitored throughout the immersion period to assess the dynamic material-environment interactions. Surface morphology, elemental composition, and chemical structure were analyzed using scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM/EDX) and Fourier-transform infrared spectroscopy (FTIR), while corrosion resistance was evaluated through electrochemical measurements. The results revealed distinct pH-dependent surface responses, with acidic saliva promoting localized surface modifications and increased corrosion susceptibility, whereas neutral conditions favored the formation of stable and protective passive layers, and alkaline environments promoted the development of chemically complex surface layers that exhibited initial stabilization but underwent progressive degradation during long-term exposure. Overall, the Zr-2.5Nb alloy demonstrated a high degree of corrosion resistance and chemical stability, particularly under neutral and alkaline conditions, supporting its suitability for dental and oral biomedical applications. These findings provide a biomimetic perspective on pH-driven surface adaptation and long-term corrosion behavior, highlighting how dynamic material-environment interactions govern the performance of zirconium-based biomaterials in complex oral environments.

Indexed as

artificial salivabiomimeticsdental biomaterialsoral corrosionpH-dependent degradationZr–2.5Nb alloy

Identifiers

PMID41892099
PMCPMC13023958

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.