Evidence map›Paper›PMID 41891420›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026

Miniaturized 3D Magnetic Force Sensor via Laser-Assisted Folding and Magnetization for Enhanced Robotic Dexterity.

Yujie Huang, Huangzhe Dai, Chengqian Zhang, Daofan Tang, Xinxin Zhang, Haonan Sun, Annan Ding, Xuebin Ni, Yizhi Zhang, Chengfeng Pan and 1 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yujie HuangState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Huangzhe DaiState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Chengqian ZhangState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.ORCID https://orcid.org/0000-0002-7581-4098
Daofan TangState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Xinxin ZhangState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Haonan SunState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Annan DingState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Xuebin NiState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Yizhi ZhangState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Chengfeng PanState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.
Peng ZhaoState Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China.ORCID https://orcid.org/0000-0002-3815-1248

Funding

National Natural Science Foundation of China 524B2062National Natural Science Foundation of China 52575460National Natural Science Foundation of China U25A20420Zhejiang provincial teams of leading talents in Innovation and Entrepreneurship 2024R01002
6 · The paper itself

Abstract

Magnetic tactile sensor with centripetally magnetization designs is capable of efficient 3D force decoupling sensing, which is essential for advancing robotic dexterity. Nevertheless, the miniaturization of sensors remains a challenge, primarily due to the complexities associated with precisely fabricating such planar magnetic structures. Here, we present a laser-assisted folding and magnetization (LAFM) method to create centripetally magnetized films. Laser-etched grooves enable controlled folding, achieving accurate magnetization alignment in films as small as 5 × 5 mm

Indexed as

3D forcelaser‐assisted foldingmagnetic force sensorsrobotic manipulation

Identifiers

PMID41891420
PMCPMC13205680

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.