Evidence map›Paper›PMID 41891149›Full record

ArticlePacing and clinical electrophysiology : PACE2026

Apical Lead Position Increases the Risk of Right Ventricular Lead Perforation: A Retrospective Cohort Study.

Yuji Manabe, Tabito Kino, Shunichi Asano, Tomoyuki Fukuzawa, Shingo Tanaka, Jun Osada, Shinya Kowase, Hajime Aoki, Kazuhiko Yumoto

Abstract read
In one paragraph

Article in Pacing and clinical electrophysiology : PACE, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yuji ManabeDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.ORCID https://orcid.org/0009-0004-2849-2243
Tabito KinoDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.
Shunichi AsanoDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.
Tomoyuki FukuzawaDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.
Shingo TanakaDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.
Jun OsadaDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.
Shinya KowaseDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.ORCID https://orcid.org/0000-0002-3576-759X
Hajime AokiDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.
Kazuhiko YumotoDepartment of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRight ventricular (RV) lead perforation is a rare but potentially life-threatening complication of cardiac implantable electronic devices. Although apical lead placement has been proposed as a risk factor, its clinical significance remains uncertain. This study evaluated whether apical RV lead positioning increases perforation risk and characterized the clinical features, diagnosis, and outcomes of affected patients.

methodsWe retrospectively reviewed data from 1,923 patients who underwent RV lead implantation between January 2002 and June 2023. Patients were categorized into Apex and Non-apex groups according to lead tip location. RV lead perforation cases were identified based on chest radiography findings. Baseline characteristics and the incidence and management of lead perforation were analyzed.

resultsAmong the 1,923 patients, 503 (26.2%) were assigned to the Apex group and 1,420 (73.8%) to the Non-apex group. RV lead perforation occurred in 5 patients (0.26%): 4 in the Apex group and 1 in the Non-apex group (0.79% vs. 0.07%, p = 0.018). Perforations were diagnosed intraoperatively or within 1-3 days post-implantation, primarily using chest computed tomography. Clinical presentations ranged from asymptomatic findings to chest pain. All patients underwent percutaneous RV lead extraction and revision, without major complications.

conclusionApical RV lead positioning was significantly associated with an increased risk of lead perforation. Although perforation was uncommon, prompt diagnosis and individualized management ensured favorable outcomes. Careful attention to lead tip location during implantation may help mitigate this risk. Given the small number of events, this finding should be interpreted as hypothesis-generating.

Indexed as

Defibrillators, ImplantableElectrodes, ImplantedHeart InjuriesHeart VentriclesPacemaker, ArtificialAgedDevice Lead ExtractionFemaleHumansMaleMiddle AgedRetrospective StudiesRisk Factorscardiac implantable electronic deviceslead positionpercutaneous lead extractionright ventricular lead perforation

Identifiers

PMID41891149
PMCPMC13542336

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.