Evidence map›Paper›PMID 41890320›Full record

ArticleEuropean heart journal. Case reports2026

Unexpected rupture of the left ventricular wall following surgical repair of post-infarction ventricular septal rupture in a patient supported by Impella CP: a case report.

Risa Nishio, Yusuke Takei, Yuya Nozawa, Toshiyuki Kuwata, Ikuko Shibasaki

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Risa NishioDivision of Cardiovascular Medicine, Japanese Red Cross Maebashi Hospital, 389-1 Asakura-machi, Maebashi, Gunma 371-0811, Japan.ORCID https://orcid.org/0009-0001-2743-3733
Yusuke TakeiDivision of Cardiovascular Surgery, Japanese Red Cross Maebashi Hospital, 389-1 Asakura-machi, Maebashi, Gunma 371-0811, Japan.ORCID https://orcid.org/0000-0002-1307-2164
Yuya NozawaDivision of Cardiovascular Surgery, Japanese Red Cross Maebashi Hospital, 389-1 Asakura-machi, Maebashi, Gunma 371-0811, Japan.ORCID https://orcid.org/0009-0008-1621-638X
Toshiyuki KuwataDivision of Cardiovascular Surgery, Japanese Red Cross Maebashi Hospital, 389-1 Asakura-machi, Maebashi, Gunma 371-0811, Japan.ORCID https://orcid.org/0000-0002-2865-831X
Ikuko ShibasakiDepartment of Cardiac and Vascular Surgery, Dokkyo Medical University School of Medicine, 880 Kitakobayashi, Mibu-machi, Shimotuga-gun, Tochigi 321-0293, Japan.ORCID https://orcid.org/0000-0002-4017-8503

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Percutaneous ventricular assist devices (pVADs) are important systems in the management of cardiogenic shock, providing effective left ventricular (LV) unloading and enabling preoperative stabilization in critically ill patients. Specifically, their use has expanded to postinfarction ventricular septal rupture (VSR), allowing for delayed surgical intervention once myocardial fibrosis progresses. Nonetheless, mechanical complications associated with prolonged pVAD support, including LV perforation, are rare but potentially fatal. Case summary: A 70-year-old woman developed VSR following an anterior myocardial infarction involving the left anterior descending artery. Preoperatively, the patient was supported with an Impella CP for 7 days. Although the device functioned normally, frequent premature ventricular contractions were noted during support. The patient underwent surgical VSR repair via the right ventricular approach using the extended sandwich patch technique. The Impella CP was removed before aortic cross-clamping. After patch closure and successful weaning from the cardiopulmonary bypass, sudden bleeding was observed in the posterior LV free wall. Re-arrest occurred, and surgical inspection revealed a 1.5-cm subepicardial rupture in the posterior wall, suspected to have resulted from mechanical contact with the Impella catheter tip. The rupture site was repaired using felt-reinforced sutures and surgical sealant. The patient later required temporary mechanical support due to low-output syndrome, but recovered gradually with preserved LV function and no VSR recurrence. Discussion: Even with a pigtail-tipped pVAD, inadequate positioning and prolonged support can lead to LV wall injuries. Careful monitoring, positional assessment, and surgical awareness are essential to avoid such complications.

Indexed as

Case reportImpella CPLeft ventricular perforationMechanical circulatory supportPercutaneous ventricular assist devicesVentricular septal rupture

Identifiers

PMID41890320
PMCPMC13014365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.