Evidence map›Paper›PMID 41888699›Full record

ArticleBMC cardiovascular disorders2026

Development and temporal validation of a two-stage ECG-based machine learning model for LVEF screening: a Middle Eastern cohort study.

Mohammed E Khalil, Adam M Khalil, Mo'ath Bani Ali, Rami Bani Ata, Abdelrahman Zamzam, Mohammad Qadura

Abstract readValidation Study
In one paragraph

Article in BMC cardiovascular disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohammed E KhalilHeart and Vascular Institute, Cleveland Clinic, Al Maryah Island, PO Box 112412, Abu Dhabi, United Arab Emirates. KhalilM3@clevelandclinicabudhabi.ae.
Adam M KhalilHeart and Vascular Institute, Cleveland Clinic, Al Maryah Island, PO Box 112412, Abu Dhabi, United Arab Emirates.
Mo'ath Bani AliHeart and Vascular Institute, Cleveland Clinic, Al Maryah Island, PO Box 112412, Abu Dhabi, United Arab Emirates.
Rami Bani AtaHeart and Vascular Institute, Cleveland Clinic, Al Maryah Island, PO Box 112412, Abu Dhabi, United Arab Emirates.
Abdelrahman ZamzamDivision of Vascular Surgery, Unity Health Toronto, St. Michael's Hospital, University of Toronto, Toronto, ON, Canada.
Mohammad QaduraHeart and Vascular Institute, Cleveland Clinic, Al Maryah Island, PO Box 112412, Abu Dhabi, United Arab Emirates.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHeart failure is a global health burden, yet artificial intelligence (AI) screening tools for left ventricular ejection fraction (LVEF) have largely been validated in Western populations with limited data from the Middle East. We aimed to develop and validate an interpretable-first, two-stage ECG-based machine learning pipeline to screen for reduced LVEF (Stage 1) and stratify its severity (Stage 2) in a large, diverse Middle Eastern cohort.

methodsWe conducted a retrospective study of 37,233 unique patients from a quaternary-care center in the United Arab Emirates (UAE). The cohort was split into a development set (n = 29,108; 2015–2023) and an independent temporal validation set (n = 8,125; 2024–2025). Stage 1 utilized a logistic regression model to screen for any reduced LVEF (< 52% in men, < 54% in women). Stage 2 applied an XGBoost classifier to positive screens to grade severity as mild (LVEF 41–51% in men, 41–53% in women), moderate (30–40%), or severe (< 30%).

resultsReduced LVEF was present in 18.0% of the overall cohort (17.5% of the development set and 18.6% of the validation set. In the validation cohort, Stage 1 achieved an AUC of 0.82 (95% CI 0.81–0.83) with sensitivity 84% (95% CI 82–86%), specificity 80% (95% CI 78–81%), negative predictive value 91% (95% CI 90–93%), and positive predictive value 68% (95% CI 66–70%). Stage 2 attained 72% overall accuracy; recall for mild, moderate, and severe dysfunction was 74%, 71%, and 72%, respectively, mirroring performance in the internal test set.

conclusionThis two-stage AI-ECG workflow provides an interpretable-first and robust method for heart failure screening in a non-Western population. With a high NPV and temporal stability, the model effectively rules out disease and triages severity, offering a scalable “ECG-first” strategy to prioritize echocardiography resources.

Indexed as

Decision Support TechniquesElectrocardiographyHeart FailureMachine LearningPredictive Learning ModelsStroke VolumeVentricular Dysfunction, LeftVentricular Function, LeftAgedFemaleHumansMaleMiddle AgedPredictive Value of TestsPrognosisReproducibility of ResultsArtificial intelligenceElectrocardiogramHeart failureLeft ventricular ejection fractionMachine learning

Identifiers

PMID41888699
PMCPMC13147717

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.