Evidence map›Paper›PMID 41884179›Full record

ArticleJournal of hand surgery global online2026

Biocompatibility, Durability, and Stability Assessment of an Unconstrained Metacarpophalangeal Joint Prosthesis With Zirconia (ZrO

Agung Riyanto Budi Santoso, Respati Suryanto Dradjat, Edi Mustamsir, Setyawan Purnomo Sakti, Panji Sananta, Hidayat Sujuti, Heri Suroto

Abstract read
In one paragraph

Article in Journal of hand surgery global online, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Agung Riyanto Budi SantosoDoctoral Program in Medical Sciences, Faculty of Medicine, Universitas Brawijaya, Malang, Indonesia.
Respati Suryanto DradjatDepartment of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Brawijaya-Dr. Saiful Anwar General Hospital, Malang, Indonesia.
Edi MustamsirDepartment of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Brawijaya-Dr. Saiful Anwar General Hospital, Malang, Indonesia.
Setyawan Purnomo SaktiDepartment of Physics, Faculty of Mathematics and Natural Science, Universitas Brawijaya, Malang, Indonesia.
Panji SanantaDepartment of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Brawijaya-Dr. Saiful Anwar General Hospital, Malang, Indonesia.
Hidayat SujutiDepartment of Ophthalmology, Faculty of Medicine, Universitas Brawijaya-Dr. Saiful Anwar General Hospital, Malang, Indonesia.
Heri SurotoDepartment of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Airlangga-Dr. Soetomo Academic General Hospital, Surabaya, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Rheumatoid arthritis often affects the metacarpophalangeal (MCP) joints, resulting in pain, deformity, and loss of hand function. In advanced disease, arthroplasty provides superior functional outcomes compared with arthrodesis. The development of small joint prostheses remains a challenge, particularly in terms of long-term durability, biocompatibility, and stability. Methods: A novel unconstrained MCP joint prosthesis was designed with zirconia crowns on the metacarpal side and polyether-ether-ketone (PEEK) crowns on the proximal phalanx, each supported by stainless steel stems. Biocompatibility was assessed histologically, whereas durability and stability were evaluated through mechanical testing, including measurements of surface roughness, weight and volume changes, and wear resistance. Functional stability was assessed by measuring in vivo flexion-extension and abduction-adduction ranges of motion and comparing them with those of conventional AISI 316L stainless steel prostheses. Results: The zirconia-PEEK prosthesis demonstrated superior biocompatibility with reduced macrophage infiltration and greater osteoblast activity. Mechanical testing revealed significantly lower wear and minimal changes in surface roughness, whereas functional testing demonstrated preserved joint mobility. Conclusions: The unconstrained zirconia-PEEK MCP prosthesis demonstrated excellent biocompatibility, superior durability, and enhanced functional stability compared with stainless steel implants, supporting its potential as a promising alternative for MCP joint replacement. Clinical relevance: This study demonstrates the potential of a zirconia-PEEK prosthesis for MCP joint replacement, potentially improving long-term functional outcomes for patients with advanced rheumatoid arthritis. Its superior biocompatibility and reduced wear characteristics may reduce complications, such as implant failure and the need for revision surgery, ultimately enhancing patient quality of life.

Indexed as

arthroplastymetacarpophalangeal jointpolyether-ether-ketonerheumatoid arthritiszirconia

Identifiers

PMID41884179
PMCPMC13011202

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.